

DPA MMC2011 Twin Diaphragm Cardioid Microphone Capsule
PRICE - Rs. 82,622
DPA MMC2011 twin diaphragm cardioid capsule for the modular pencil series: directional, well-balanced sound with any DPA pencil preamp. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is inclusive of all taxes. Contact / WhatsApp +91 89818 07755 / +91 91477 00677 to check if any offers or additional discounts are available. If available, we will gladly share a coupon code that you can apply at checkout for the best price. All payments are processed securely through Razorpay, our trusted payment gateway.
Capsule
| Type | Twin diaphragm cardioid pencil microphone capsule |
| Directional pattern | Cardioid |
| Sound | Well balanced |
| Compatible preamps | MMP-A, MMP-C, MMP-ER/ES (XLR) or MMP-GR/GS (MicroLock) |
| Part number | MMC2011 |
Product overview
The DPA MMC2011 is a twin diaphragm cardioid capsule for the DPA modular pencil microphone series, a directional capsule with a distinctive, well-balanced sound.
The capsule bridges the gap between the extreme sound quality of the DPA pencil microphone series and the well-known DPA miniature lavalier and headset microphones.
You can combine it with any DPA modular pencil preamp: the ultra-transparent, transformerless MMP-A, the ultra-compact MMP-C, the MMP-ER/ES active XLR cable with rear or side cable entry, or the MMP-GR/GS active MicroLock cable for wireless systems.
| Pickup pattern | Cardioid |
| Capsule design | Twin diaphragm |
| Capsule | Directional |
| Fits every DPA pencil preamp | Modular |
Key features
- Twin diaphragm cardioid capsule
- Directional pickup
- Distinctive, well-balanced sound
- Part of the DPA modular pencil microphone series
- Combines with the MMP-A, MMP-C, MMP-ER/ES and MMP-GR/GS preamps
Made for
- Building or reconfiguring a DPA pencil microphone
- Studio and stage recording with a directional pickup
- Hanging and table microphones on active cables
- Wireless set-ups via the MicroLock active cable
In the box
- MMC2011 microphone capsule (a DPA pencil preamp is needed, available separately)
DPA MMC2011: frequently asked questions
Is the MMC2011 a complete microphone?
It is a capsule of the modular pencil microphone series. Combine it with any DPA pencil preamp: the MMP-A standard preamp, the MMP-C compact preamp, the MMP-ER/ES active XLR cable or the MMP-GR/GS active MicroLock cable.
What is the character of the MMC2011?
It is a directional cardioid capsule with a distinctive, well-balanced sound that bridges the gap between the DPA pencil microphone series and the DPA miniature lavalier and headset microphones.
Can I use it with a wireless system?
Yes. On the MMP-GR/GS active cable it has a MicroLock connector, which links it to wireless systems through the range of DPA adapters.
Can it be used in stereo?
Yes. Two capsules on MMP-ER/ES or MMP-GR/GS active cables fit the CXO4000 Compact XY/ORTF Stereo Holder.
Where can I buy the DPA MMC2011 in India?
The DPA MMC2011 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Pencil microphone with the MMP-A
Studio and stage engineers who want a full-size pencil microphone.
Connections
| Connect | To |
|---|---|
| MMC2011 | MMP-A preamp |
| MMP-A XLR output | Microphone input |
Setup
- Combine the capsule with the MMP-A, an ultra-transparent, transformerless preamp.
- Connect the XLR output to the microphone input.
- Use the 20 dB attenuation push switch at the XLR connector when needed.
Tip: Active drive gives impedance balancing over the cable.
Workflow 2: Compact set-up with the MMP-C
Engineers who need a short, discreet microphone.
Connections
| Connect | To |
|---|---|
| MMC2011 | MMP-C compact preamp |
| MMP-C | Microphone input |
Setup
- Combine the capsule with the ultra-compact MMP-C.
- Place the microphone where space is tight.
- Connect and set the gain.
Tip: The MMP-C has a slightly softer character than the other preamps in the series.
Workflow 3: Hanging or table microphone
Recording and broadcast engineers needing unobtrusive hanging or table microphones.
Connections
| Connect | To |
|---|---|
| MMC2011 | MMP-ER or MMP-ES active XLR cable |
| CSM4000 compact shock mount | Microphone stand, TB4000 or MB4000 |
Setup
- Fit the capsule on the MMP-ER (rear cable) or MMP-ES (side cable).
- Hang it, or suspend it in the CSM4000 on a stand, table base or magnet base.
- Connect the 3-pin XLR to the input.
Tip: The preamp sits in a small 12 mm housing for a very slim set-up.
Workflow 4: Wireless with the MMP-GR/GS
Broadcast, theatre and live crews working with wireless systems.
Connections
| Connect | To |
|---|---|
| MMC2011 | MMP-GR or MMP-GS active MicroLock cable |
| MicroLock connector | DPA adapter for the bodypack transmitter |
Setup
- Fit the capsule on the MMP-GR (rear cable) or MMP-GS (side cable).
- Connect the MicroLock connector through the matching DPA adapter.
- Set the transmitter input level.
Tip: The MMP-G lets a larger microphone feed a wireless transmitter directly.
Workflow 5: Instrument miking with the GSM4000
Musicians and engineers close-miking acoustic instruments.
Connections
| Connect | To |
|---|---|
| MMC2011 on MMP-ER/ES or MMP-GR/GS | GSM4000 gooseneck shock mount |
| GSM4000 | DPA instrument clip |
Setup
- Mount the capsule on the active cable in the GSM4000.
- Attach the GSM4000 to the instrument with the matching clip.
- Bend the 11.5 cm gooseneck to aim the capsule.
Tip: The gooseneck and shock mount are combined in one piece.
Workflow 6: XY or ORTF stereo pair
Recording engineers capturing ensembles and ambience in stereo.
Connections
| Connect | To |
|---|---|
| 2 x MMC2011 on MMP-ER/ES or MMP-GR/GS | CXO4000 stereo holder |
| CXO4000 | Microphone stand |
Setup
- Fit both capsules on active cables.
- Mount them in the CXO4000 in XY or ORTF configuration.
- Connect both channels and match the gains.
Tip: XY is coincident; ORTF is near-coincident and combines time and intensity differences.








