DPA ST4011A Matched Stereo Pair, 4011A Cardioid Microphones product guide and data sheet
‹
DPA ST4011A Matched Stereo Pair, 4011A Cardioid Microphones product guide and data sheet
›

Brand: DPA

DPA ST4011A Matched Stereo Pair, 4011A Cardioid Microphones

PRICE - Rs. 5,50,285

Category: Stereo Microphone Sets | Series: MICROPHONE KITS

DPA ST4011A matched stereo pair of 4011A cardioid pencil microphones, ±1 dB, phase below 10°, accurate sound for studio and stage. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.


WhatsApp
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)

The price shown is inclusive of all taxes. Contact / WhatsApp +91 89818 07755 / +91 91477 00677 to check if any offers or additional discounts are available. If available, we will gladly share a coupon code that you can apply at checkout for the best price. All payments are processed securely through Razorpay, our trusted payment gateway partner.


TECHNICAL SPECIFICATIONTech SpecsDESCRIPTIONDescriptionREAL-WORLD WORKFLOWSReal-World Workflows

Acoustics (each 4011A)

Directional patternCardioid
Principle of operationPressure gradient
Cartridge typePre-polarised condenser
Frequency response20 Hz - 20 kHz
Effective frequency range ±2 dB, at 30 cm (11.8 in)40 Hz - 20 kHz
Sensitivity, nominal, ±2 dB at 1 kHz10 mV/Pa; -40 dB re. 1 V/Pa
Equivalent noise level, A-weightedTyp. 18 dB(A) re. 20 µPa (max. 20 dB(A))
Equivalent noise level, ITU-R BS.468-4Typ. 25 dB (with the attenuator at 0 dB or -20 dB)
Distortion, THD < 1 %136 dB SPL RMS, 139 dB SPL peak
Dynamic rangeTyp. 121 dB
Max. SPL, THD 10 %159 dB SPL peak

Electrical (each 4011A)

Switchable attenuator0 dB / -20 dB
Rated output impedance200 Ω
Cable drive capability100 m (328 ft)
Output balance principleImpedance balancing with Active Drive
Common mode rejection ratio (CMRR)> 60 dB
Power supply (for full performance)P48 phantom power
Current consumption2.8 mA
Maximum output voltage, RMS> 5 V
ConnectorXLR-3M. Pin 1: shield, pin 2: signal + phase, pin 3: - phase
Polarity+V at pin 2 for positive sound pressure

Physical (each 4011A)

Weight158 g (5.6 oz)
Microphone diameter19 mm (0.75 in)
Capsule diameter19 mm (0.75 in)
Microphone length170 mm (6.7 in)
Temperature range-40 °C to 45 °C (-40 °F to 113 °F)
Relative humidity (RH)Up to 90 %
ColourMatte black

Stereo pair

Matching tolerance (frequency response and sensitivity)±1 dB
Phase deviation for kit< 10°

Versions

ST4011AMatched stereo pair, 2 x 4011A Cardioid Mic

Product overview

The DPA ST4011A is a matched stereo pair of 4011A Cardioid Microphones, matched to ±1 dB in frequency response and sensitivity, with a phase deviation below 10° for the kit.

The 4011 is renowned in recording studios and live applications around the world. State-of-the-art components have been carefully selected to provide optimal neutrality, accuracy and extremely low distortion. The principal appeal of the 4011 is its directional quality and attention to detail: it makes everything sound like the original. The first-order cardioid pickup pattern provides superb separation between sound sources, and it can handle incredibly high sound pressure levels. A flat on-axis frequency response and excellent phase response deliver a faithful reproduction of the original sound; the off-axis response is similarly smooth, so any leakage is an accurate reflection of the original, attenuated according to the true first-order cardioid pattern.

The 4011A is equally suitable for close-up work on acoustic guitar, grand piano, overheads, percussion, wind instruments and vocals, as well as spot-miking symphonies. Each microphone includes a 20 dB pad switch in the centre of the XLR connector, runs on P48 phantom power and has a balanced output with Active Drive.

Matched stereo pair 2 x 4011A
Matching tolerance ±1 dB
Phase deviation for kit < 10°
Max. SPL peak, THD 10 % 159 dB

Key features

  • Two 4011A microphones matched to ±1 dB, phase deviation below 10°
  • Accurate, colourless sound: optimal neutrality and extremely low distortion
  • True first-order cardioid with superb separation between sound sources
  • Flat on-axis response, excellent phase response and a smooth off-axis response
  • Great for high sound pressure levels: 159 dB SPL peak at THD 10 % (4011A)
  • 20 dB pad switch on each microphone

Made for

  • Acoustic guitar, grand piano and overheads
  • Percussion, wind instruments and vocals
  • Spot-miking symphonies
  • Studio and live applications

In the box

  • 2 x DPA 4011A Cardioid Microphone (matched stereo pair)

DPA ST4011A: frequently asked questions

How closely are the two microphones matched?

Frequency response and sensitivity are matched within ±1 dB, and the phase deviation for the kit is below 10°.

What is the pair good for?

Close-up work on acoustic guitar, grand piano, overheads, percussion, wind instruments and vocals, as well as spot-miking symphonies.

How does it handle leakage?

The true first-order cardioid gives superb separation, and the smooth off-axis response keeps any leakage an accurate, attenuated reflection of the original.

Can the microphones take loud sources?

Yes. Each 4011A reaches 159 dB SPL peak at THD 10 % and has a 20 dB pad switch.

Where can I buy the DPA ST4011A in India?

The DPA ST4011A is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.

Workflow 1: Stereo overheads

Engineers miking drum kits.

Connections

ConnectTo
4011A pairAbove the kit
4011A pair (XLR-3M)Two inputs with P48, panned left and right

Setup

  1. Place the matched pair over the kit.
  2. Use the 20 dB pads for loud playing.
  3. Connect, pan and balance.

Tip: Matching within ±1 dB keeps the stereo image even.

Workflow 2: Grand piano in stereo

Studio and live engineers.

Connections

ConnectTo
4011A pairOver the piano
4011A pairTwo microphone preamps with P48

Setup

  1. Place the pair over the strings.
  2. Connect both.
  3. Pan and set matching gains.

Tip: Flat on-axis and excellent phase response for a faithful sound.

Workflow 3: Acoustic guitar

Recording engineers.

Connections

ConnectTo
4011A pairGuitar, two positions
4011A pairTwo inputs

Setup

  1. Place the two microphones on the instrument.
  2. Connect them.
  3. Record and pan.

Tip: The 4011 makes everything sound like the original.

Workflow 4: Spot-miking a symphony

Recording and broadcast engineers.

Connections

ConnectTo
4011AOrchestra section
4011AConsole input

Setup

  1. Place the microphones at the sections to spot.
  2. Connect.
  3. Blend with the main pickup.

Tip: The first-order cardioid gives superb separation between sound sources.

Workflow 5: Vocals and wind instruments

Studio engineers.

Connections

ConnectTo
4011ASinger or wind player
4011AMicrophone preamp with P48

Setup

  1. Place the microphone in front of the source.
  2. Connect and set the gain.
  3. Record.

Tip: Accurate, colourless sound with extremely low distortion.

Workflow 6: Reconfigure with another DPA preamp

Owners who change set-ups between jobs.

Connections

ConnectTo
4011 capsuleAny DPA pencil preamp
4011 capsuleMMP-G modular active cable to a wireless transmitter

Setup

  1. Unscrew the capsule.
  2. Fit the preamp for the job.
  3. Connect.

Tip: Like all DPA modular pencil microphones, the capsule combines with any DPA preamp.

Request a Quote

DPA ST4011A Matched Stereo Pair, 4011A Cardioid Microphones

Explore all the categories

Studio to stage, every category —

View all ›

Explore all the brands

Genuine gear from leading audio brands —

View all ›