PRICE ON ENQUIRY. For the price, exclusive offers, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share a personalised quotation for Shivansh Electronics, Kolkata, West Bengal, India. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Microphone and audio
| Microphone type | Non‑removable gooseneck condenser microphone |
| Polar pattern | Unidirectional |
| Frequency response | 50 Hz - 18 kHz (-10 dB) |
| Output level | -24 dBV at 104 dB SPL; -34 dBV at 94 dB SPL |
| SNR | 70 dB at 1 kHz / 1 Pa |
| Page mute | 80 dB typical |
| Audio output | Balanced, detachable 3 pole screw terminal |
| Maximum audio cable length | Twisted pair 5 m; shielded 60 m |
Control and power
| Number of paging zones | 1 |
| Control output | Open drain N channel MOSFET, N.C. / N.O. internally selectable |
| Control rating | Max. +48 V DC / 0.1 A |
| Control connector | Detachable 2 pole screw terminal |
| Phantom power supply | +10 to +48 V DC |
| Power consumption | 2 mA |
Physical
| Installation | Desktop |
| Operating temperature | -10 °C to 40 °C |
| Operating humidity | Below 85 % RH |
| Dimensions (W x D x H) | 120 x 126 x 43 mm (microphone excluded) |
| Weight | 625 g |
| Shipping dimensions (W x H x D) | 240 x 165 x 190 mm |
| Shipping weight | 1.0 kg |
Product overview
The ECLER MPAGE1r is a one-zone desktop paging station, compatible with any device that has a phantom-powered microphone input, such as the SAM / eSAM series, DAM614, MIMO / MIMO SG series, CA series and HMA / eHMA series.
Press and hold the PAGE key and speak: the gooseneck condenser microphone sends the message in real time over a balanced screw-terminal output, powered by the receiver's phantom supply. A PAGE ACTIVE trigger output (N.O. / N.C. selectable) can mute music or switch external equipment while you page, and all connections sit inside the base for secure wiring.
| PAGE key | 1 zone |
| Phantom powered, 2 mA | +10 to +48 V |
| Microphone response (-10 dB) | 50 Hz - 18 kHz |
| SNR at 1 kHz / 1 Pa | 70 dB |
Key features
- 1 zone paging station with PAGE key
- Gooseneck condenser microphone, unidirectional, with anti-pop windscreen
- Balanced audio output on a detachable 3 pole screw terminal
- PAGE ACTIVE trigger (GPO), N.O. / N.C. internally selectable
- Internal connections for a secure wiring
- Powered by phantom power from the receiver (+10 to +48 V DC, 2 mA)
- Page mute 80 dB typical
- Windscreen and connectors included (microphone cable not included)
Works with any phantom-powered input
Connect the MPAGE1r to the microphone input of an ECLER mixer amplifier, mixer or matrix (SAM / eSAM, DAM614, MIMO / MIMO SG, CA, HMA / eHMA series) or any device with phantom power.
Simple installation
- Remove the bottom screw and slide the bottom plate to reach the connectors
- Pass the cable through the rubber grommet
- Wire + (live), - (cold) and ground to the balanced output
- Adjust the microphone level on the receiver
Trigger for talkover
Wire the TRIGGER output to a GPI or MUTE input, for example the MUTE function of a MIMO88 through a GPI input or the MUTE input of a SAM mixer, to attenuate the music in the paged area while the PAGE key is pressed.
Where it fits
Paging, voice messages and speech.
In the box
- 1 x MPAGE1r paging station
- 1 x windscreen
- Connectors
Available versions
- MPAGE1r: reference CMPAGE1R
ECLER MPAGE1r: frequently asked questions
Does the MPAGE1r need a power supply?
No. It is powered by the phantom power (+10 to +48 V DC, 2 mA) of the receiving microphone input.
Is the microphone cable included?
No. The windscreen and connectors are included; the microphone cable is not.
How long can the cable be?
Up to 5 m with twisted pair cable, or up to 60 m with shielded cable.
What does the trigger output do?
It is an open drain MOSFET output (max. +48 V DC / 0.1 A), N.O. or N.C., active while PAGE is pressed, to control external equipment such as a mute or talkover input.
Where can I buy the ECLER MPAGE1r in India?
The ECLER MPAGE1r is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Shop announcements on a mixer amplifier
Calls over background music in a store.
Connections
| Connect | To |
|---|---|
| MPAGE1r output | Phantom‑powered mic input of the mixer amplifier |
| TRIGGER (N.O.) | Mixer MUTE input |
Setup
- Open the base and pass the cable through the grommet.
- Wire +, - and ground.
- Set the trigger jumper to N.O. and wire it to the MUTE input.
- Adjust the microphone level on the mixer.
Tip: Use shielded cable for runs up to 60 m.
Workflow 2: Matrix paging with talkover
Paging into a MIMO88 zone.
Connections
| Connect | To |
|---|---|
| MPAGE1r output | MIMO88 microphone input with phantom |
| TRIGGER | MIMO88 GPI input |
Setup
- Wire the audio to the matrix input.
- Wire the trigger to a GPI.
- Program the GPI to mute the zone music.
- Test with the PAGE key.
Tip: With N.O. the trigger is active while PAGE is pressed.
Workflow 3: Reception desk
A receptionist calls staff in one area.
Connections
| Connect | To |
|---|---|
| MPAGE1r | Amplifier microphone input |
| Amplifier | Area loudspeakers |
Setup
- Place the station on the desk.
- Wire it to the amplifier input.
- Enable phantom power on the input.
- Set the call level.
Tip: The receiver must supply phantom power.
Workflow 4: Automatic talkover
A receiver with automatic level detection.
Connections
| Connect | To |
|---|---|
| MPAGE1r | Receiver microphone input |
| Receiver talkover | Level detection mode |
Setup
- Wire the audio only.
- Enable talkover on the receiver.
- Press PAGE and speak.
- Check how much the music is attenuated.
Tip: Music is attenuated only while the voice is detected.
Workflow 5: School office
Announcements to one zone from the office.
Connections
| Connect | To |
|---|---|
| MPAGE1r | Mixer amplifier input |
| Amplifier | Corridor loudspeakers |
Setup
- Install the station on the office desk.
- Keep twisted pair runs within 5 m, or use shielded cable.
- Wire and set the level.
- Train staff to hold PAGE while speaking.
Tip: Page mute is 80 dB typical when PAGE is released.
Workflow 6: Switching external equipment
Light a sign or switch a relay while paging.
Connections
| Connect | To |
|---|---|
| TRIGGER | External control input |
| Audio output | Receiver input |
Setup
- Select N.O. or N.C. with the internal jumper.
- Wire the 2 pole trigger terminal.
- Stay within +48 V DC / 0.1 A.
- Test the switching.
Tip: The trigger is a MOSFET output, not a power-free contact.