ECLER MPAGE1r product guide and data sheet cover
‹
ECLER MPAGE1r product guide and data sheet coverECLER MPAGE1r data sheet page 2: Overview and key featuresECLER MPAGE1r data sheet page 3: Control panel functionsECLER MPAGE1r data sheet page 4: Installation: audio wiringECLER MPAGE1r data sheet page 5: Installation: PAGE ACTIVE trigger outputECLER MPAGE1r data sheet page 6: OperationECLER MPAGE1r data sheet page 7: Compatible ECLER equipmentECLER MPAGE1r data sheet page 8: The gooseneck microphoneECLER MPAGE1r data sheet page 9: Technical specifications
›

Brand: ECLER

ECLER MPAGE1r

PRICE ON ENQUIRY

Category: Paging Microphones | Series: PAGING STATIONS

ECLER MPAGE1r one-zone desktop paging station: gooseneck condenser microphone, PAGE key, balanced output, trigger output, phantom powered. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.


VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)

PRICE ON ENQUIRY. For the price, exclusive offers, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share a personalised quotation for Shivansh Electronics, Kolkata, West Bengal, India. All payments are processed securely through Razorpay, our trusted payment gateway partner.


TECHNICAL SPECIFICATIONTech SpecsDESCRIPTIONDescriptionREAL-WORLD WORKFLOWSReal-World Workflows

Microphone and audio

Microphone typeNon‑removable gooseneck condenser microphone
Polar patternUnidirectional
Frequency response50 Hz - 18 kHz (-10 dB)
Output level-24 dBV at 104 dB SPL; -34 dBV at 94 dB SPL
SNR70 dB at 1 kHz / 1 Pa
Page mute80 dB typical
Audio outputBalanced, detachable 3 pole screw terminal
Maximum audio cable lengthTwisted pair 5 m; shielded 60 m

Control and power

Number of paging zones1
Control outputOpen drain N channel MOSFET, N.C. / N.O. internally selectable
Control ratingMax. +48 V DC / 0.1 A
Control connectorDetachable 2 pole screw terminal
Phantom power supply+10 to +48 V DC
Power consumption2 mA

Physical

InstallationDesktop
Operating temperature-10 °C to 40 °C
Operating humidityBelow 85 % RH
Dimensions (W x D x H)120 x 126 x 43 mm (microphone excluded)
Weight625 g
Shipping dimensions (W x H x D)240 x 165 x 190 mm
Shipping weight1.0 kg

Product overview

The ECLER MPAGE1r is a one-zone desktop paging station, compatible with any device that has a phantom-powered microphone input, such as the SAM / eSAM series, DAM614, MIMO / MIMO SG series, CA series and HMA / eHMA series.

Press and hold the PAGE key and speak: the gooseneck condenser microphone sends the message in real time over a balanced screw-terminal output, powered by the receiver's phantom supply. A PAGE ACTIVE trigger output (N.O. / N.C. selectable) can mute music or switch external equipment while you page, and all connections sit inside the base for secure wiring.

PAGE key 1 zone
Phantom powered, 2 mA +10 to +48 V
Microphone response (-10 dB) 50 Hz - 18 kHz
SNR at 1 kHz / 1 Pa 70 dB

Key features

  • 1 zone paging station with PAGE key
  • Gooseneck condenser microphone, unidirectional, with anti-pop windscreen
  • Balanced audio output on a detachable 3 pole screw terminal
  • PAGE ACTIVE trigger (GPO), N.O. / N.C. internally selectable
  • Internal connections for a secure wiring
  • Powered by phantom power from the receiver (+10 to +48 V DC, 2 mA)
  • Page mute 80 dB typical
  • Windscreen and connectors included (microphone cable not included)

Works with any phantom-powered input

Connect the MPAGE1r to the microphone input of an ECLER mixer amplifier, mixer or matrix (SAM / eSAM, DAM614, MIMO / MIMO SG, CA, HMA / eHMA series) or any device with phantom power.

Simple installation

  • Remove the bottom screw and slide the bottom plate to reach the connectors
  • Pass the cable through the rubber grommet
  • Wire + (live), - (cold) and ground to the balanced output
  • Adjust the microphone level on the receiver

Trigger for talkover

Wire the TRIGGER output to a GPI or MUTE input, for example the MUTE function of a MIMO88 through a GPI input or the MUTE input of a SAM mixer, to attenuate the music in the paged area while the PAGE key is pressed.

Where it fits

Paging, voice messages and speech.

In the box

  • 1 x MPAGE1r paging station
  • 1 x windscreen
  • Connectors

Available versions

  • MPAGE1r: reference CMPAGE1R

ECLER MPAGE1r: frequently asked questions

Does the MPAGE1r need a power supply?

No. It is powered by the phantom power (+10 to +48 V DC, 2 mA) of the receiving microphone input.

Is the microphone cable included?

No. The windscreen and connectors are included; the microphone cable is not.

How long can the cable be?

Up to 5 m with twisted pair cable, or up to 60 m with shielded cable.

What does the trigger output do?

It is an open drain MOSFET output (max. +48 V DC / 0.1 A), N.O. or N.C., active while PAGE is pressed, to control external equipment such as a mute or talkover input.

Where can I buy the ECLER MPAGE1r in India?

The ECLER MPAGE1r is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.

Workflow 1: Shop announcements on a mixer amplifier

Calls over background music in a store.

Connections

ConnectTo
MPAGE1r outputPhantom‑powered mic input of the mixer amplifier
TRIGGER (N.O.)Mixer MUTE input

Setup

  1. Open the base and pass the cable through the grommet.
  2. Wire +, - and ground.
  3. Set the trigger jumper to N.O. and wire it to the MUTE input.
  4. Adjust the microphone level on the mixer.

Tip: Use shielded cable for runs up to 60 m.

Workflow 2: Matrix paging with talkover

Paging into a MIMO88 zone.

Connections

ConnectTo
MPAGE1r outputMIMO88 microphone input with phantom
TRIGGERMIMO88 GPI input

Setup

  1. Wire the audio to the matrix input.
  2. Wire the trigger to a GPI.
  3. Program the GPI to mute the zone music.
  4. Test with the PAGE key.

Tip: With N.O. the trigger is active while PAGE is pressed.

Workflow 3: Reception desk

A receptionist calls staff in one area.

Connections

ConnectTo
MPAGE1rAmplifier microphone input
AmplifierArea loudspeakers

Setup

  1. Place the station on the desk.
  2. Wire it to the amplifier input.
  3. Enable phantom power on the input.
  4. Set the call level.

Tip: The receiver must supply phantom power.

Workflow 4: Automatic talkover

A receiver with automatic level detection.

Connections

ConnectTo
MPAGE1rReceiver microphone input
Receiver talkoverLevel detection mode

Setup

  1. Wire the audio only.
  2. Enable talkover on the receiver.
  3. Press PAGE and speak.
  4. Check how much the music is attenuated.

Tip: Music is attenuated only while the voice is detected.

Workflow 5: School office

Announcements to one zone from the office.

Connections

ConnectTo
MPAGE1rMixer amplifier input
AmplifierCorridor loudspeakers

Setup

  1. Install the station on the office desk.
  2. Keep twisted pair runs within 5 m, or use shielded cable.
  3. Wire and set the level.
  4. Train staff to hold PAGE while speaking.

Tip: Page mute is 80 dB typical when PAGE is released.

Workflow 6: Switching external equipment

Light a sign or switch a relay while paging.

Connections

ConnectTo
TRIGGERExternal control input
Audio outputReceiver input

Setup

  1. Select N.O. or N.C. with the internal jumper.
  2. Wire the 2 pole trigger terminal.
  3. Stay within +48 V DC / 0.1 A.
  4. Test the switching.

Tip: The trigger is a MOSFET output, not a power-free contact.