







ECLER VIDA-24Q
MRP - Rs. 5,55,900
ECLER VIDA-24Q 2400 W 4-channel Class D amplifier: VersaPower, 100/70 V or 2-8 Ω per output, Dante/AES67, DSP, matrix, microSD player, web control. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Power
| All channels driven (1 kHz, CF 9 dB, 1 % THD) | 4 x 600 W at 8 Ω, 4 Ω, 2 Ω, 100 V, 70 V |
| Single channel driven | 1400 W at 8 Ω; 2400 W at 4 Ω, 2 Ω and 100 V; 2000 W at 70 V |
| Amplification | Class D, efficiency 72 % |
| Output modes | Lo‑Z / Hi‑Z: 100 V, 70 V, 8 Ω, 4 Ω, 2 Ω per channel |
Signal and DSP
| Inputs | 4 analogue (3‑pin Euroblock, balanced), 4 Dante/AES67, player, generator |
| Outputs | 4 amplified (2‑pin Euroblock 7.62 mm), 2 auxiliary (balanced), 4 Dante/AES67 |
| Voltage gain | 28 to 40 dBV |
| Input sensitivity | -6 to +6 dBV |
| Input impedance | Above 24 kΩ, balanced |
| Max input level | +18 dBV (+20.2 dBu) |
| Frequency response | 15 Hz - 25 kHz (-3 dB) |
| THD + noise | Below 0.1 % (0.015 % typ.) |
| SNR | 95 dBA |
| Crosstalk | Above 80 dB |
| Damping factor | Above 500 |
| Converters | 24 bit, 48 kHz, 114 dB dynamic range |
| Latency | 2.8 ms analogue in to analogue out |
| Processing | Inputs: noise gate, HPF, frequency shifter, compressor/limiter; outputs: delay, parametric and graphic EQ, limiters |
Network, control and player
| Ethernet | NET1‑2, 10/100/1000 Mb, auto X‑over |
| Dante/AES67 | 4 Tx / 4 Rx (2/2 flows) |
| Programming | Embedded web application |
| GPI / GPO | 4 x 0‑10 V / 4 x NO‑NC relays |
| External mute | Contact |
| Player | microSD SDXC up to 2 TB; mp3, ogg, WAV, FLAC, AIFF |
Electrical and physical
| Mains | 100‑240 V, 50‑60 Hz, PFC above 0.96, IEC C14 |
| 1/4 power at 4 Ω (230 V) | 848 W, 888 VA, 3.88 A |
| Protections | DC, HF, short circuit, clip limiter, long term limiter, thermal |
| Cooling | Fan, front to back |
| Operating temperature | -10 °C to 50 °C |
| Dimensions (W x H x D) | 482.6 x 88 x 410 mm |
| Weight | 9.3 kg |
| Shipping weight | 12.3 kg |
Product overview
The ECLER VIDA-24Q is a 2400 W Class D digital amplifier with 4 amplified outputs, each independently configurable for high (100/70 V) or low (8/4/2 Ω) impedance, with Dante/AES67 networking, DSP, an internal matrix and an audio player.
ECLER VersaPower technology distributes the 2400 W asymmetrically among the outputs, and the Smart VersaPower tool sets gain and sensitivity automatically. It offers 4 analogue and 4 Dante/AES67 inputs, a microSD audio player, a signal generator, 2 auxiliary line outputs and 4 Dante/AES67 outputs. Everything is managed from the embedded web application: routing, processing, priorities, GPIO events, calendar events and playlists, while end users control their zones from the ECLER VIDA app or a web browser.
| VersaPower total power | 2400 W |
| All channels driven | 4 x 600 W |
| Per output | 100 / 70 V · 2‑8 Ω |
| 19 inch rack or desktop | 2 RU |
Key features
- 4 VersaPower amplified outputs, 2400 W asymmetrical power management
- High or low impedance per output: 100 V, 70 V, 8 Ω, 4 Ω or 2 Ω, set on rear DIP switches
- 4 Dante/AES67 inputs and 4 outputs, 4 analogue inputs, 2 auxiliary outputs
- microSD audio player and signal generator
- Internal matrix and DSP: gate, HPF, compressor, delay, parametric and graphic EQ, limiters
- Embedded web application, user panels, scheduled events and presets
- 4 GPI, 4 GPO and external mute for wall panels and automation
- Energy saving: auto standby per output and sleep mode; EclerCLOUD compatible
VersaPower
The total power can go where it is needed: 600 W on each of the four outputs, or most of the 2400 W on one output. Smart VersaPower adjusts gain and sensitivity to share out the power quickly.
Sources and routing
Four balanced analogue inputs, four Dante/AES67 network channels, the internal player and the signal generator feed a digital matrix to the amplified, auxiliary and network outputs. Priority and backup signals, local and network groups and calendar events automate the system.
Control for installers and users
NET1 carries control (web application, user panels, third-party control) and NET2 carries control plus Dante/AES67 audio. Front panel knobs are programmable, WPa wall panels connect to the GPI ports, and EclerCLOUD allows remote monitoring.
In the box
- 1 x VIDA-24Q
- Power cord and multi plugs
- Euroblock connectors (inputs / outputs)
- Desktop feet and 19 inch rack installation hardware
- First steps guide
- Warranty card
ECLER VIDA-24Q: frequently asked questions
Can each output drive a 100 V line?
Yes. Each of the 4 outputs is set independently for 100 V, 70 V, 8 Ω, 4 Ω or 2 Ω on the rear OUT MODE switches.
How is it configured?
From the embedded web application in any browser; end users can use the ECLER VIDA app or web access with panels created by the installer.
Does it include Dante?
Yes. The Dante/AES67 licence is included, with 4 transmit and 4 receive channels.
Can it play background music on its own?
Yes. The built-in player plays mp3, ogg, WAV, FLAC and AIFF files from a microSD card, with playlists and calendar events.
Where can I buy the ECLER VIDA-24Q in India?
The ECLER VIDA-24Q is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Hotel background music
Lobbies, restaurants and corridors on 100 V lines.
Connections
| Connect | To |
|---|---|
| Music source or microSD | Player / IN1 |
| OUT1‑4 (100 V) | Zone loudspeaker lines |
Setup
- Set OUT MODE to 100 V.
- Route sources in the matrix.
- Run Smart VersaPower.
- Create user panels per zone.
Tip: Calendar events change music by time of day.
Workflow 2: Mixed loads
Venues with low and high impedance loudspeakers.
Connections
| Connect | To |
|---|---|
| OUT1‑2 | 70/100 V lines |
| OUT3‑4 | 8 Ω or 2 Ω loudspeakers |
Setup
- Set each output mode on the DIP switches.
- Match the total load.
- Share the power with VersaPower.
- Set limiters per output.
Tip: Never connect loads below 2 Ω.
Workflow 3: Network audio system
Installations with Dante/AES67 sources.
Connections
| Connect | To |
|---|---|
| Network switch | NET2 |
| Control network | NET1 |
Setup
- Keep NET1 and NET2 on different networks.
- Route four network channels in.
- Send zone mixes back to the network.
- Save presets.
Tip: AES67 is enabled by default.
Workflow 4: Wall panel control
Zones where staff adjust levels.
Connections
| Connect | To |
|---|---|
| WPa panels | GPI1‑4 |
| VIDA outputs | Zones |
Setup
- Wire panels to GPI ports.
- Assign volume or presets in the web app.
- Test each panel.
- Lock settings with users.
Tip: GPI cables can be up to 500 m.
Workflow 5: Emergency muting
Venues with an evacuation system.
Connections
| Connect | To |
|---|---|
| Alarm contact | EXT. MUTE |
| VIDA outputs | Zones |
Setup
- Wire the potential-free contact.
- Choose outputs to mute.
- Test with the alarm system.
- Document the set-up.
Tip: Normally open = mute off.
Workflow 6: Remote monitoring
Integrators maintaining several sites.
Connections
| Connect | To |
|---|---|
| VIDA NET1 | Internet router |
| EclerCLOUD | Integrator account |
Setup
- Register on EclerCLOUD.
- Add the device with its ID.
- Monitor status remotely.
- Plan firmware updates.
Tip: Sleep mode keeps idle consumption very low.








