The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Acoustics (MCM 114 = KK 14 with MCM 100)
| Acoustic operating principle | Pressure gradient transducer |
| Directional pattern | Cardioid |
| Frequency range | 20 Hz - 20 kHz |
| Sensitivity at 1 kHz into 1 kΩ | 3.6 mV/Pa ≅ -49 dBV ± 2 dB |
| Signal‑to‑noise ratio, CCIR (rel. 94 dB SPL) | 63 dB |
| Signal‑to‑noise ratio, A‑weighted (rel. 94 dB SPL) | 71 dB |
| Equivalent noise level, CCIR | 31 dB |
| Equivalent noise level, A‑weighted | 23 dB‑A |
| Maximum SPL for THD < 0.5 %, with MCM 100 | 153 dB SPL |
| Maximum SPL for THD < 0.5 %, Usupply = 5 V, Rfeed = 8.25 kΩ | 147 dB SPL |
| Dynamic range of the amplifier, A‑weighted | 130 dB |
Electrical
| Rated output impedance | KK 14: 10 Ω; MCM 100: 50 Ω |
| Rated load impedance | 1000 Ω |
| Power supply | KK 14: ≤ 10 V, with Rfeed = 20 kΩ; MCM 100: 48 V ± 4 V (P48, IEC 61938) |
| Current consumption | KK 14: 0.22 mA; MCM 100: 3.5 mA |
| Required connector | XLR‑3F |
Mechanical and environment
| Weight | KK 14: 2.3 g; MCM 100: 96 g |
| Dimensions (Ø x L) | KK 14: 12 mm x 12 mm; MCM 100: 22 mm x 77 mm |
| SH 100 gooseneck | Overall length 144 mm; weight 16 g |
| Operating temperature range | 0 °C to +40 °C |
| Storage temperature range | -20 °C to +70 °C |
| Operating humidity range | 0 % - 90 % |
| Storage humidity range | 0 % - 95 % |
Notes
| Noise and S/N | According to IEC 60268‑1; CCIR weighting according to CCIR 468‑3, quasi peak; A‑weighting according to IEC 61672‑1, RMS |
| Maximum SPL | THD of the microphone amplifier at an input voltage equivalent to the capsule output at the specified SPL |
Set
| Cat. No. | 008707 |
| Clip | MC 1 clip high strings |
| Gooseneck | SH 100 |
| Packing | Handy soft case |
| Colour | Black |
Product overview
The NEUMANN MCM 114 set high strings is a complete set for using the NEUMANN Miniature Clip Mic MCM system on the body of a violin, viola, mandolin or similar instrument: true Neumann sound for close miking acoustic instruments in live applications.
The set contains the KK 14 cardioid capsule head, SH 100 gooseneck, KC 1 cable brace, AC 31 cable, MCM 100 output stage, WS 110 windscreen and the MC 1 clip high strings, delivered in a handy soft case. The MCM System raises the bar of electret capsules and redefines the standard in natural sound, practicality, reliable mounting and longevity; its modular construction allows for easy replacements and guarantees a superior low cost of ownership.
| Maximum SPL for THD < 0.5 % | 153 dB SPL |
| Equivalent noise level | 23 dB‑A |
| Sensitivity at 1 kHz | 3.6 mV/Pa |
| Frequency range | 20 Hz - 20 kHz |
Key features
- KK 14 cardioid capsule with a layer-based design: eight key components, assembled by hand
- Ultra-low self-noise and up to 153 dB SPL for very quiet and very loud instruments
- Road-tough titanium housing
- MC 1 clip high strings with a gooseneck holder that locks in 45° increments
- SH 100 gooseneck, KC 1 cable brace and WS 110 windscreen
- MCM 100 output stage for wired use on any XLR input with 48 V phantom power
- AC 31 cable with 3.5 mm mini jack, also for wireless bodypack transmitters
- Delivered in a handy soft case
The capsule: 8 parts of perfection
The newly developed MCM capsules bring a new level of tonal balance, more body, especially in the bass and mid-range, and transparency in the treble. Each of the capsule's eight key components is designed for optimal performance, manufactured independently and assembled by hand. Strict quality control guarantees an unprecedented level of tonal consistency: each capsule sounds exactly the same and delivers the neutral Neumann-style sound, saving time during setup and EQ tuning, especially when running multiple microphones.
Mounting: gentle on surfaces, reliable for engineers
The MC 1 holds on the body of a violin, viola, mandolin or similar instrument (clip aperture 32 mm - 50 mm, 16 g). Its self-adjusting spring mechanism and rubber coating ensure reliable attachment without damaging the instrument. The MCM mounting mechanics are gentle on even the most sensitive surfaces and make mounting a matter of seconds, requiring only one hand for most instruments, and the gooseneck can be precisely aligned and locked to the clip in 45-degree increments.
Wired and wireless
For wired operation the MCM 100 output stage connects the AC 31 cable to an XLR microphone input with 48 V phantom power. The MCM system also offers interchangeable cable options for wireless bodypack transmitters, so no adapter is needed.
In the box
- KK 14 capsule head (cardioid)
- SH 100 gooseneck
- AC 31 (1.8 m) connection cable
- WS 110 windscreen
- MCM 100 output stage
- MC 1 clip
- KC 1 cable brace
- Safety guide
- Quick guide
- Soft case
NEUMANN MCM 114 set high strings: frequently asked questions
What is in the NEUMANN MCM 114 set high strings?
KK 14 capsule head, SH 100 gooseneck, AC 31 (1.8 m) cable, WS 110 windscreen, MCM 100 output stage, MC 1 clip, KC 1 cable brace, safety guide and quick guide, in a soft case.
What polar pattern does the set have?
The KK 14 capsule head is a pressure gradient transducer with a cardioid pattern.
Does it need phantom power?
In wired use the MCM 100 output stage is powered with 48 V ± 4 V phantom power (P48, IEC 61938), 3.5 mA.
Can I use it with a wireless system?
Yes. The AC 31 cable has a 3.5 mm mini jack for bodypack transmitters; other MCM cables are available for other transmitter inputs.
Where can I buy the NEUMANN MCM 114 set high strings in India?
The NEUMANN MCM 114 set high strings is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Live performance
Musicians and live sound engineers.
Connections
| Connect | To |
|---|---|
| KK 14 on SH 100 with MC 1 | Instrument |
| AC 31 | MCM 100 |
| MCM 100 | Console microphone input (P48) |
Setup
- Mount the MC 1 on the instrument and lock the gooseneck in the holder.
- Fit the WS 110 windscreen.
- Connect AC 31 to the MCM 100 and the MCM 100 to the console.
- Switch on P48 and set the gain.
Tip: Rotate the holder in 45° steps to aim the capsule.
Workflow 2: Wireless performance
Performers who move on stage.
Connections
| Connect | To |
|---|---|
| KK 14 on SH 100 with MC 1 | Instrument |
| AC 31 (3.5 mm) | Bodypack transmitter |
Setup
- Mount the set on the instrument.
- Route the cable along the instrument with the KC 1 cable brace.
- Plug the AC 31 into the bodypack transmitter.
- Set the transmitter input level.
Tip: With Usupply = 5 V, Rfeed = 8.25 kΩ the capsule still handles 147 dB SPL.
Workflow 3: Studio recording
Studios recording close-miked instruments.
Connections
| Connect | To |
|---|---|
| MCM 100 | Interface or preamp input (P48) |
Setup
- Mount the set on the instrument.
- Connect the MCM 100 to the interface input.
- Enable P48.
- Record a test and fine-tune the position.
Tip: The neutral Neumann sound needs little EQ.
Workflow 4: Several instruments, one sound
Ensembles running multiple MCM microphones.
Connections
| Connect | To |
|---|---|
| Several MCM sets | Console inputs (P48) |
Setup
- Fit one MCM set per instrument.
- Connect each MCM 100 to its input.
- Match gains.
- Mix.
Tip: Each capsule sounds exactly the same, which saves setup and EQ time.
Workflow 5: Loud sources
Engineers miking loud instruments close up.
Connections
| Connect | To |
|---|---|
| MCM 114 set | Console input (P48) |
Setup
- Place the capsule close to the source.
- Set the input gain so that it does not clip.
- Use the cardioid pattern to reject sound from the rear.
- Mix.
Tip: The capsule handles up to 153 dB SPL with the MCM 100.
Workflow 6: Touring and quick changeovers
Touring crews.
Connections
| Connect | To |
|---|---|
| Soft case | Complete set |
Setup
- Keep the set in its soft case.
- Mount the clip with one hand.
- Connect and check.
- Pack away after the show.
Tip: The modular system allows easy replacement of single parts.