TONEWINNER AD-5100PA+
PRICE ON ENQUIRY
Tonewinner AD-5100PA+ five-channel home theatre power amplifier: 100 W into 8 Ω and 140 W into 4 Ω per channel, five protections, trigger input. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
PRICE ON ENQUIRY. For the price, exclusive offers, delivery timelines, or any other information, please Contact / WhatsApp +91 89818 07755 / +91 91477 00677. We will gladly share a personalised quotation for Shivansh Electronics, Kolkata, West Bengal, India. All payments are processed securely through Razorpay, our secure payment gateway.
General
| Model | AD-5100PA+ |
| Type | Five-channel home theatre power amplifier |
| Channels | 5 |
Amplifier
| Amplifier output (8 Ω) | 100 W per channel (THD 1 %, 1 kHz) |
| Amplifier output (4 Ω) | 140 W per channel (THD 1 %, 1 kHz) |
| Rated impedance | 8 Ω |
| Unit gain | ≥ 28 dB |
| Circuit | Differential input and amplification, temperature compensation |
Audio performance
| THD | ≤ 0.1 % (A-weighted) |
| Signal to noise ratio | ≥ 100 dB (A-weighted, analogue through) |
| Frequency response | 20 Hz - 30 kHz (+1 / -3 dB) |
| Channel separation | ≥ 70 dB (two channels) |
Inputs and outputs
| Inputs | 5 × analogue signal input |
| Speaker outputs | 5 pairs of gold-plated binding posts |
| Trigger | Trigger in, 5-12 V |
| Indicators | Power / protection indicator, 5 signal indicators |
Protection and cooling
| Protection | Overvoltage, overheat, overload, overcurrent, short circuit |
| Cooling | Intelligent air cooling |
Power
| Power supply | ~115 V / 230 V, 60 / 50 Hz |
| Power consumption | ≤ 500 W |
Physical
| Dimensions (W × D × H) | 431 × 352 × 130 mm |
| Net weight | 9.6 kg |
| Gross weight | 12 kg |
Product overview
The Tonewinner AD-5100PA+ is a five-channel power amplifier for home theatres, designed to work with AV receivers or multi-channel preamplifiers to drive extra channels such as ceiling speakers, with 100 W into 8 Ω or 140 W into 4 Ω per channel.
Five separate amplifier channels add the extra layers a Dolby Atmos room needs: connect the AD-5100PA+ to the pre-outs of an AV receiver or processor and it powers the height, surround or back channels, so the receiver's own amplifier can concentrate on the rest. Each channel delivers 100 W into 8 Ω and 140 W into 4 Ω (1 kHz, THD 1 %).
The Hi-Fi circuit uses differential input, differential amplification and a temperature compensation circuit, suiting home theatres that need high sound pressure, wide dynamic range, strong driving and fast transmission. Signal to noise is at least 100 dB (A-weighted) and channel separation at least 70 dB.
An intelligent air-cooling system keeps the amplifier cool, and five protections cover overvoltage, overheat, overload, overcurrent and short circuit. On the front, five separate indicators show the working status of each channel and change brightness with the signal strength, while the power indicator lights blue in normal use and red when the amplifier is in protection mode.
At the back are five analogue signal inputs, five pairs of gold-plated speaker terminals, a trigger input that switches the amplifier on automatically from a 5-12 V trigger, and the mains input. The all-aluminium wire-drawn front panel, aluminium body and anti-vibration feet complete it. In Tonewinner's own 5.1.2 suggestion the AD-5100PA+ drives the surround and height channels while the AD-3240PA drives the front three.
| amplifier output into 8 Ω | 5 × 100 W |
| per channel into 4 Ω | 140 W |
| signal to noise (A-weighted) | ≥ 100 dB |
| net weight | 9.6 kg |
Key features
- Five amplifier channels for height, surround or back speakers
- Amplifier output: 100 W into 8 Ω, 140 W into 4 Ω per channel (1 kHz, THD 1 %)
- Differential input and differential amplification with temperature compensation
- Five separate signal indicators whose brightness follows the signal
- Power indicator: blue in normal use, red in protection mode
- Five protections: overvoltage, overheat, overload, overcurrent, short circuit
- Intelligent air-cooling system
- Trigger input: switches on automatically from a 5-12 V trigger
- Signal to noise ≥ 100 dB; channel separation ≥ 70 dB
- All-aluminium wire-drawn panel, gold-plated binding posts, anti-vibration feet
Made for
- AV receivers and multi-channel preamplifiers that need extra amplified channels
- Ceiling (height) channels in Dolby Atmos home theatres
- Surround and back channels in 5.1.2, 7.1.2 and larger systems
- Systems with other Tonewinner power amplifiers
In the box
- AD-5100PA+ power amplifier
- Manual (with warranty card)
- Power cord
- Certificate
- RCA cable (4 pins)
Connections
- Signal inputs: 5 × analogue (one per channel)
- Speaker outputs: 5 pairs of gold-plated binding posts
- Trigger input (5-12 V)
- AC power input
Tonewinner AD-5100PA+: frequently asked questions
What is the AD-5100PA+ used for?
It adds five amplified channels to an AV receiver or multi-channel preamplifier, typically for the ceiling (height) channels or the surround channels of a home theatre.
How much power does each channel give?
100 W into 8 Ω and 140 W into 4 Ω per channel at 1 kHz, THD 1 %, according to the spec table. Rated impedance is 8 Ω.
Will it turn on with my receiver?
Yes. Connect a 5-12 V trigger output from the receiver or processor to the trigger input and the amplifier powers on automatically.
What does a red indicator mean?
The power indicator is blue in normal working status and turns red when the amplifier is in protection mode, for example if an amplifier module is abnormal. Connect all inputs and outputs before switching on; plugging signal cables in or out while it runs can cause a false protection, solved by restarting.
Where can I buy the Tonewinner AD-5100PA+ in India?
The Tonewinner AD-5100PA+ is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Ceiling channels for a Dolby Atmos room
Home theatre owners adding height speakers.
Connections
| Connect | To |
|---|---|
| AV receiver height pre-outs | AD-5100PA+ inputs |
| AD-5100PA+ speaker outputs | Ceiling speakers |
| Receiver trigger out | AD-5100PA+ trigger in |
Setup
- Connect the receiver's height pre-outs to the AD-5100PA+ inputs.
- Wire the ceiling speakers to the matching gold-plated terminals.
- Connect the trigger cable (5-12 V) for automatic power-on.
- Rerun the receiver's room calibration.
Tip: Connect all cables before switching on to avoid a false protection.
Workflow 2: 5.1.2 system with two Tonewinner amplifiers
Owners building a fully separate amplification system.
Connections
| Connect | To |
|---|---|
| Processor L / R / C | AD-3240PA |
| Processor surround and height outputs | AD-5100PA+ |
Setup
- Let the AD-3240PA drive the front three channels.
- Let the AD-5100PA+ drive two surround and two height channels.
- Chain the trigger so both start with the processor.
- Calibrate the system from the processor.
Tip: This is the 5.1.2 arrangement suggested by Tonewinner.
Workflow 3: Surround and back channels upgrade
7.1 systems where the receiver runs out of power.
Connections
| Connect | To |
|---|---|
| Receiver surround and back pre-outs | AD-5100PA+ inputs |
| AD-5100PA+ | Surround and back speakers |
Setup
- Connect up to five pre-outs.
- Move the speaker cables to the amplifier.
- Check the five signal indicators light with sound.
- Adjust levels in the receiver.
Tip: The indicators get brighter with stronger signals, an easy check that every channel works.
Workflow 4: Multi-zone background music
Homes that want music in extra rooms from a multi-channel source.
Connections
| Connect | To |
|---|---|
| Preamplifier or matrix outputs | AD-5100PA+ inputs |
| AD-5100PA+ | Speakers in other rooms |
Setup
- Feed each zone's signal into one or two inputs.
- Connect each room's speakers.
- Set the levels at the source.
- Use the trigger for automatic start.
Tip: Rated impedance is 8 Ω; 4 Ω speakers get 140 W per channel.
Workflow 5: Rack installation
Installers placing the amplifier in a cabinet.
Connections
| Connect | To |
|---|---|
| AD-5100PA+ | Ventilated rack shelf |
Setup
- Allow airflow for the intelligent air-cooling system.
- Keep it on a dry, well-ventilated shelf away from water, oil and smoke.
- Check the mains voltage setting matches the supply.
- Use the trigger to avoid switching it on and off too often.
Tip: Wait a few minutes before switching on again after turning off.
Workflow 6: Fault check
Anyone whose amplifier shows a red indicator.
Connections
| Connect | To |
|---|---|
| AD-5100PA+ | Speakers and source |
Setup
- Switch off and check every input and speaker connection.
- Look for shorted speaker wires.
- Switch on again: the indicator should be blue.
- If it stays red, contact a professional service centre.
Tip: Never open the unit yourself; it is Class II equipment.