ART HVA1 product guide and data sheet cover
‹
ART HVA1 product guide and data sheet coverART HVA1 data sheet page 2: Overview and key featuresART HVA1 data sheet page 3: Controls and connectionsART HVA1 data sheet page 4: Specifications
›

Brand: ART

ART HVA1

MRP - Rs. 61,182

Category: Power Amplifiers | Series: POWER AMPLIFIERS

ART HVA1 two-channel Class D installation amplifier: 135 W per channel on 70 V or 100 V lines, built-in limiter, Euroblock audio and control, 1U. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.


Quantity:

−1+
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)

The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.


TECHNICAL SPECIFICATIONTech SpecsDESCRIPTIONDescriptionREAL-WORLD WORKFLOWSReal-World Workflows

Specifications

Amplifier classSwitching power, Class D
Output power135 W per channel x 2, 70 V or 100 V line, all channels driven
Frequency response120 Hz - 17 kHz (-3 dB)
THD< 0.1 %
Signal to noise ratio> 95 dB
Damping factor> 200
Crosstalk> 70 dB
Voltage gain (100 V)40 dB
Input impedance20 kΩ (balanced); 10 kΩ (unbalanced)
Input sensitivity0.9 - 1.1 V (0 ± 1 dBV)
ProtectionShort circuit, open circuit, thermal, ultrasonic and RF
ConnectorsEuroblock input and output
Control pinsFail, DIS, PRI, Test, GND (on the Euroblock input)
ControlsFront: AC switch, level control per channel; rear: 70 V / 100 V selector
IndicatorsSignal (green), Clip (red), Power (green), Protection (red), Prior (green / red)

Power and physical

Power supplyAC 110‑240 V, 50/60 Hz
Rack space1U, 19 inch
Dimensions (W x H x D)48.3 x 4.4 x 36.0 cm (19.02 x 1.73 x 14.17 inch)
Weight4.7 kg (10.36 lb)

Product overview

The ART HVA1 is a two-channel Class D amplifier for 70 V and 100 V installations that delivers 135 watts per channel.

Each channel has an independent level control and status LEDs for signal activity, clipping and thermal protection, and its operation mode (70 V or 100 V line) is selected with rear DIP switches. With a robust feature set in a 1U rackmount enclosure, the HVA1 offers a built-in limiter, an internal fan and Euroblock connectors for audio, status and control signals: the outputs can be disabled remotely, a priority input lets a test or alarm signal override the programme on all outputs, and a failure status output reports when the unit is disabled or in protect mode.

70 V / 100 V line, all channels driven 2 x 135 W
Switchable per channel 70 V / 100 V
Frequency response (-3 dB) 120 Hz - 17 kHz
1U rackmount 4.7 kg

Key features

  • 2-channel Class D power amplifier (switching power)
  • Switchable 70 V / 100 V operation
  • 135 W per channel
  • Euroblock connectors for input, output, status and control
  • Built-in limiter
  • Short circuit, thermal and power on / off muting protection
  • Remote disable, priority test / alarm input and failure status output
  • Front mounted level controls and Signal, Clip, Protect and Power LEDs
  • 1U rackmount, 19 inch

Front panel

The front panel carries the power switch, a level control for each channel and the indicators: the Signal LED (green) shows signal present in the channel, the Clip LED (red) shows that the input signal is too high and the Protection LED turns red in thermal protection, when the speaker load is disconnected from the amplifier outputs until the amplifier is back at a safe temperature. The Power / Protect LED in the level control is green in normal operation and red in protect mode. Air is drawn in through the front grilles for the variable-speed internal fan and exhausted through the rear vents.

Rear panel and control pins

The Euroblock input takes balanced or unbalanced signals for CH A and CH B, and the speaker outputs are also on Euroblock connectors. The control pins of the input block are Fail (failure status output: normally +5 V, 0 V if the unit is disabled or in protect mode), DIS (grounding it disables the amplifier and lights all protection lights), PRI (grounding it gives the Test input priority; the level knobs then turn from green to red), Test (the test / alarm signal that overrides all inputs and appears on all outputs when priority is active) and GND. The mains input with its fuse holder sits on the right.

Applications

ART's manual shows the HVA1 driving two zones of 100 V line loudspeakers connected in parallel, with a separate audio source for each zone or the same audio on both, plus a priority control and a test / alarm source wired to the control pins.

In the box

  • HVA1 power amplifier
  • Power cord (determined by the country of operation, per the owner's manual)

ART HVA1: frequently asked questions

Can the HVA1 run 70 V and 100 V lines?

Yes. The operation mode (70 V or 100 V) is selected for each channel with the rear DIP switches.

How much power does it deliver?

135 W per channel, on 70 V or 100 V lines, with all channels driven.

Can a paging or alarm signal override the music?

Yes. When the PRI pin is grounded, the signal on the Test input has priority, overrides all inputs and is present on all outputs.

What mains voltage does it need?

ART's manual states AC 110-240 V, 50/60 Hz.

Where can I buy the ART HVA1 in India?

The ART HVA1 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.

Workflow 1: Two-zone 100 V background music

Shops, restaurants and offices with two loudspeaker zones.

Connections

ConnectTo
Audio source 1CH A input (Euroblock)
Audio source 2CH B input (Euroblock)
CH A / CH B speaker outputs100 V line loudspeakers of zone 1 / zone 2, in parallel

Setup

  1. Set the DIP switches of both channels to 100 V.
  2. Wire the loudspeakers of each zone in parallel to its output.
  3. Set each zone's level with the front controls.

Tip: The same source can also feed both zones.

Workflow 2: 70 V line installation

Installations designed for 70 V loudspeaker lines.

Connections

ConnectTo
Mixer or preamplifierHVA1 Euroblock inputs
HVA1 outputs70 V line loudspeakers

Setup

  1. Set the operation mode DIP switches to 70 V.
  2. Connect the loudspeaker lines to the Euroblock outputs.

Tip: The mode is selected for each channel, so one channel can run 70 V and the other 100 V.

Workflow 3: Alarm or test signal with priority

Systems where an alarm or announcement must override the programme.

Connections

ConnectTo
Test / alarm sourceTest pin
Priority contactPRI and GND pins

Setup

  1. Wire the alarm signal to the Test pin.
  2. Ground the PRI pin through the priority contact when the alarm must play.

Tip: With priority active, the level knobs turn from green to red.

Workflow 4: Remote disable

Installations with a central control system.

Connections

ConnectTo
Control contactDIS and GND pins

Setup

  1. Ground the DIS pin to disable the amplifier.
  2. Disable the unit or power it down before connecting or disconnecting speaker loads.

Tip: All protection lights come on while the amplifier is disabled.

Workflow 5: Failure monitoring

Integrators who need a status signal from the amplifier.

Connections

ConnectTo
Fail pinMonitoring input of the control system

Setup

  1. Read the Fail output: normally +5 V.
  2. Treat 0 V as unit disabled or in protect mode.

Tip: The Fail output is part of the Euroblock input connector.

Workflow 6: Rack installation

Installers mounting the HVA1 in a 19 inch rack.

Connections

ConnectTo
HVA11U rack space

Setup

  1. Keep the front grilles and rear exhaust vents clear.
  2. Use the mains voltage setting that matches the supply (AC 110-240 V, 50/60 Hz per ART).

Tip: Air flows in through the front, through the heat sink and out of the rear vents.

Explore all the categories

Studio to stage, every category —

View all ›

Explore all the brands

Genuine gear from leading audio brands —

View all ›