ECLER DARA-4B900 product guide and data sheet cover
‹
ECLER DARA-4B900 product guide and data sheet coverECLER DARA-4B900 data sheet page 2: Overview and key featuresECLER DARA-4B900 data sheet page 3: Front and rear panelsECLER DARA-4B900 data sheet page 4: Connections and output modesECLER DARA-4B900 data sheet page 5: DSP, matrix and web controlECLER DARA-4B900 data sheet page 6: Technical specifications (official ECLER data sheet)
›

Brand: ECLER

ECLER DARA-4B900

MRP - Rs. 3,51,900

Category: Power Amplifiers | Series: DARA SERIES

ECLER DARA-4B900 networkable Class D amplifier: 4 x 900 W at 4 Ω, 70/100 V or bridge per pair, DSP with 4 x 4 matrix, dual Ethernet. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.


Quantity:

−1+
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)

The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.


TECHNICAL SPECIFICATIONTech SpecsDESCRIPTIONDescriptionREAL-WORLD WORKFLOWSReal-World Workflows

Channels and output power

Output channels4
Output connectorsEuroblock, 4‑pin per channel pair, pitch 5.08 mm
Output configuration2 Ω, 4 Ω, 8 Ω, 100 V, 70 V; 4/8 Ω bridge
Input channels4, balanced, 3‑pin Euroblock, pitch 3.5 mm
Input configurationDigital matrix 4 in x 4 out
Power at 8 Ω550 W
Power at 4 Ω900 W
Power at 2 Ω1600 W
Power at 4 Ω bridge3200 W
Power at 8 Ω bridge1600 W
Power at 100 V900 W
Power at 70 V900 W
ConditionsAll channels or single channel driven, 1 kHz, crest factor 9 dB, 1 % THD

Signal

Voltage gain36 dB
Input sensitivity0 dBV (2.21 dBu, 1 V RMS)
Input impedance20 kΩ, balanced
Maximum input level+23 dBu
Frequency response15 Hz - 22 kHz (-3 dB, 1 W, any load)
THD + noise< 0.1 % (1 kHz, 0.1 W to full power)
Signal to noise ratio97.8 dBA
Crosstalk> 90 dB (1 kHz)
CMRR> 52 dB typical (20 Hz - 20 kHz)

DSP

Converters24 bit, 48 kHz; AD 105 dB‑A, DA 120 dB
Internal precision32 bit floating point
Dynamic range112 dB
Latency1.5 ms
Presets15 amplifier presets; 40 speaker presets (22 ECLER + 18 custom)
Delay20 ms (input) + 300 ms (output)
Input processingDelay, parametric and graphic EQ, compressor
Output processingDelay, parametric and graphic EQ, polarity, compressor, FIR filters, RMS and peak limiter

Control and connectivity

GPI4 x 0 - 10 V
External muteContact closure
Ethernet100Base‑TX, CAT5 up to 100 m; second RJ45 for daisy‑chaining
ProgrammingEmbedded web application
Remote controlECLER PULSO series app
Front panelAssignable level knobs, power switch, per‑channel LEDs
Auto standbyThreshold -40 dB, time 90 s
ProtectionsAC, DC, HF, short‑circuit, clip limiter, thermal

Power and physical

Power supplyUniversal, regulated SMPS with PFC
AC mains100 - 240 V, 50 - 60 Hz (±10 %), IEC C14 inlet
Power factor> 0.96
AmplificationClass D
Efficiency74 % (1/4 power, 4 Ω)
Cooling2 fans, maximum fan noise 57 dBA
Consumption, 1/4 power, 4 Ω (230 V)1236 W, 1300 VA, 5.7 A
Consumption, 1/8 power, 4 Ω (230 V)692.5 W, 744 VA, 3.25 A
Consumption, Idle (230 V)100 W, 163 VA, 0.71 A
Consumption, Sleep mode (230 V)4.8 W, 81 VA, 0.35 A
Operating temperature-20 °C to 40 °C
Operating humidity10 - 90 % RH, non‑condensing
Installation19 inch rack (1 RU) or desktop
Dimensions (W x H x D)484 x 44 x 411.6 mm with handles; 484 x 44 x 378 mm without
Weight7.65 kg
Shipping dimensions590 x 80 x 590 mm
Shipping weight10.74 kg
ReferenceCDARA4B900

Product overview

The ECLER DARA-4B900 is a high-performance, network-enabled Class D power amplifier for professional audio installations, delivering up to 4 x 900 W RMS at 4 Ω to low impedance loudspeakers or 70 V / 100 V lines, with bridge mode, configured by pairs of channels.

An integrated DSP with an internal 4 x 4 matrix and dual Ethernet ports with an embedded switch give precise audio management and easy integration into scalable networked systems. The amplifier is set up from its embedded web application and is fully compatible with the ECLER PULSO series, so users can control and monitor it from a mobile app or a web interface. Auto standby saves energy, and complete protections (thermal, overload, short-circuit, clip) keep it reliable in fixed installations.

RMS at 4 Ω 4 x 900 W
and 70 V / 100 V, per pair 2 / 4 / 8 Ω
DSP digital matrix 4 x 4
19 inch rack or desktop 1 RU

Key features

  • 4-channel Class D power amplifier with high-efficiency design
  • 4 x 900 W RMS at 4 Ω output power
  • 2 Ω, 4 Ω, 8 Ω, 70 V, 100 V and bridge mode, configurable by channel pairs
  • 4 balanced analogue inputs with internal 4 x 4 digital matrix
  • Integrated DSP with ECLER loudspeaker EQ presets included
  • Dual Ethernet ports with integrated switch for daisy-chaining
  • Embedded web interface and ECLER PULSO series remote control
  • Auto standby function for energy savings
  • Protections: thermal, overload, short-circuit, clip
  • Safety Euroblock connections and software-lockable front panel

Low and high impedance on the same amplifier

An OUT MODE switch on the rear panel sets each channel pair to 2 Ω, 4 Ω or 8 Ω, to 70 V or 100 V lines, or to 4/8 Ω bridge mode (with the supplied Euroblock jumper). Per channel the DARA-4B900 delivers 550 W at 8 Ω, 900 W at 4 Ω, 1600 W at 2 Ω and 900 W on 70 V or 100 V lines; in bridge mode a channel pair delivers 3200 W at 4 Ω or 1600 W at 8 Ω.

DSP and matrix

Inputs have delay, parametric and graphic EQ and a compressor; outputs add polarity, custom FIR filters and RMS and peak limiters. The matrix routes any input to any output with its own level, and 15 amplifier presets plus 40 speaker presets (22 ECLER and 18 custom) make set-up quick.

Networked control

Two RJ45 ports (100Base-TX) give access to the web application and let several DARA units share one network link by daisy-chaining. 4 GPI ports (0 - 10 V) take wall panels for remote volume, an external mute input reacts to a contact closure, and users and custom control panels can be created with their own permissions.

In the box

  • 1 x DARA unit
  • 1 x EU power cord and 1 x IEC power cord with UK, US and CN plug adapters
  • 6 x Euroblock connectors (4 x 3-pin blue for inputs, 2 x 4-pin green for outputs)
  • 2 x Euroblock jumpers
  • 4 x desktop feet
  • 1 x external mute connector
  • 1 x remote volume connector (GPI)
  • 1 x 19 inch rack installation hardware
  • 1 x First Steps Guide
  • 1 x warranty card

ECLER DARA-4B900: frequently asked questions

Can it drive 100 V line loudspeakers?

Yes. Each channel pair can be set to 70 V or 100 V with the rear OUT MODE switch, giving up to 900 W per channel.

Can channels be bridged?

Yes. Bridge mode at 4 Ω or 8 Ω is configured per channel pair; insert the supplied Euroblock jumper first. A bridged pair delivers up to 3200 W at 4 Ω.

How is the amplifier configured?

From its embedded web application, opened in a browser over Ethernet; end users can control it through the ECLER PULSO series app.

Can several amplifiers share one network cable?

Yes. The two RJ45 ports include a switch, so several DARA units can be daisy-chained.

Where can I buy the ECLER DARA-4B900 in India?

The ECLER DARA-4B900 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.

Workflow 1: Retail store on 100 V lines

Shops with ceiling loudspeakers in several areas.

Connections

ConnectTo
Background music sourceIN 1 - 2
OUT 1 - 2 (pair set to 100 V)Sales floor ceiling loudspeakers
OUT 3 - 4 (pair set to 70 V or 100 V)Stock room and fitting rooms

Setup

  1. Set the OUT MODE switch of each pair to 100 V before powering up.
  2. Route the inputs to the outputs in the web application matrix.
  3. Set the output levels and limiters.
  4. Lock the front panel.

Tip: Never connect loads below 2 Ω in low impedance mode.

Workflow 2: Restaurant with low impedance speakers

Dining room and bar zones with 8 Ω loudspeakers.

Connections

ConnectTo
Music playerIN 1
Host microphone mixerIN 2
Outputs (pairs set to 8 Ω)Zone loudspeakers

Setup

  1. Set the channel pairs to 8 Ω.
  2. Load the ECLER speaker preset of each loudspeaker.
  3. Mix music and microphone per zone in the matrix.
  4. Assign the front knobs to the zone volumes.

Tip: Speaker presets include ECLER loudspeaker EQ settings.

Workflow 3: Bridged power for a subwoofer

Venues that need more power on one loudspeaker.

Connections

ConnectTo
Programme sourceIN 1
Bridged channel pair (4 Ω or 8 Ω)Subwoofer

Setup

  1. Insert the supplied Euroblock jumper on the output connector.
  2. Set the OUT MODE switch of the pair to bridge.
  3. Apply crossover filters and limiters in the DSP.
  4. Check polarity before switching on.

Tip: A bridged pair delivers up to 3200 W at 4 Ω.

Workflow 4: Wall panel volume control

Meeting rooms and classrooms where staff adjust the volume.

Connections

ConnectTo
0 - 10 V wall panelGPI port
Amplifier outputRoom loudspeakers

Setup

  1. Wire the panel to the GPI Euroblock (+10 V, control, ground).
  2. Assign the GPI to the room output in Knobs and GPI.
  3. Choose direct or reverse mode.
  4. Test the range.

Tip: GPI cables can run up to 500 m with 0.5 mm² wire.

Workflow 5: Fire alarm muting

Installations that must fall silent on an alarm.

Connections

ConnectTo
Alarm panel relay (potential‑free contact)EXT.MUTE

Setup

  1. Wire the contact to the EXT.MUTE port.
  2. Assign the affected outputs in the web application.
  3. Trigger a test and check the mute LEDs.

Tip: Closed contact = mute on; open = mute off.

Workflow 6: Several amplifiers on one network

Larger sites with a rack of DARA amplifiers.

Connections

ConnectTo
Network switchNET port of the first DARA
Second NET portNET port of the next DARA (daisy‑chain)

Setup

  1. Connect the first unit to the network.
  2. Daisy-chain the others through the second RJ45 port.
  3. Open each unit by IP address or host name.
  4. Update firmware and give each unit a name.

Tip: Units work in DHCP mode by default; hold RESET for 10 s to restore network settings.