ECLER eHMA120
MRP - Rs. 98,900
ECLER eHMA120 powered mixer: 95 W on 4 Ω or 70/100 V, two switchable zones, four inputs, talkover, chime, battery backup input. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Power output
| Low Z output | 95 W at 4 Ω, 1 % THD |
| 100 V output | 95 W at 100 Ω, 1 % THD |
| Zones | 2 high impedance zones with ON / OFF switches |
| Frequency response | 70 Hz - 25 kHz (-3 dB, HPF at 70 Hz) |
| THD + noise | < 0.2 % |
| Crosstalk | > 65 dB at 1 kHz |
Inputs
| LINE 2 - 4 | -15 to +15 dBV, > 10 kΩ, double RCA |
| MIC 1 - 3 | -50 to -20 dBV, > 1 kΩ, balanced Euroblock |
| CMRR (MIC) | > 65 dB at 1 kHz |
| Phantom | +24 V DC, 10 mA max. |
| Signal to noise | LINE > 85 dB; MIC > 75 dB |
Control and supply
| Tone control | Bass 100 Hz, treble 10 kHz, ±15 dB |
| Talkover | Inputs 1, 2, 3; 2 s, -30 dB |
| Mute | Normally open, dry contact |
| Supply | 24 V DC; 100 - 240 V AC with the supplied PSU; 24 V DC battery input |
| Consumption | 1/8 power 47 VA / 26 W; 1/3 power 64 VA / 58 W; standby < 5 W |
Physical
| Dimensions (W x H x D) | 435 x 44 x 120 mm (knobs excluded) |
| Weight | 2.9 kg |
| Shipping dimensions | 320 x 70 x 580 mm |
| Shipping weight | 4.2 kg |
| Reference | CEHMA120C |
Product overview
The ECLER eHMA120 is a self-powered audio mixer with a 95 W mono output for 4 Ω loudspeakers or 70 V / 100 V lines, with independent ON / OFF switches for two zones.
It has four inputs (a MIC input, two MIC/LINE inputs and a stereo LINE input) with talkover on inputs 1 to 3, an embedded chime triggered by dry contact for one-zone paging microphones, a 2-band tone control, auto standby, a MUTE port, +24 V phantom power, an AUX/REC output and a universal 24 V DC power supply with a battery backup input. A rack mount kit is included.
| 4 Ω or 70 / 100 V | 95 W |
| ON / OFF switches | 2 zones |
| Inputs | 4 |
| Dry contact trigger | Chime |
Key features
- 1 x 95 W at 4 Ω and 1 x 95 W at 70 V / 100 V
- 2 x ZONE ON / OFF switches
- Talkover on inputs 1, 2 and 3
- Pager input with embedded chime
- 2-band EQ for the mix
- 24 V DC power supply included, with external battery backup connector
- +24 V DC phantom power
- MUTE port, AUX/REC output and auto standby
- Rack mount kit included
Two zones from one amplifier
ZONE 1 and ZONE 2 high impedance outputs each carry a 70 V or 100 V loudspeaker line, switched on or off from the front panel, while LOW-Z OUT serves 4 Ω loudspeakers.
Paging with chime
Closing a dry contact on CHIME TRIGGER plays a chime before a message from a microphone or a paging station, with its own volume control; talkover lowers the music by 30 dB.
Backup power
The mixer runs from its 24 V DC power supply and has a separate 24 V DC battery input for backup systems.
In the box
- 1 x eHMA120 powered mixer
- 1 x 24 V DC external power supply
- 1 x rack mount kit
ECLER eHMA120: frequently asked questions
How many zones does it have?
Two high impedance zones, each with a front ON / OFF switch, plus a low impedance output.
Can a paging station trigger a chime?
Yes. A dry contact on the CHIME TRIGGER input plays a chime with adjustable volume.
Can it run from batteries?
Yes. It has an external 24 V DC battery supply input for backup.
What is the output power?
95 W at 4 Ω and 95 W on 70 V / 100 V lines (official data sheet).
Where can I buy the ECLER eHMA120 in India?
The ECLER eHMA120 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Shop background music with announcements
Retail stores with ceiling loudspeakers.
Connections
| Connect | To |
|---|---|
| Music player | LINE input (RCA) |
| Paging microphone | MIC input with talkover |
| HIGH‑Z OUT 100 V | Ceiling loudspeaker line |
Setup
- Connect the 100 V loudspeaker line to 0 V and 100 V.
- Set the microphone input GAIN.
- Switch on TK for the microphone input.
- Set OUTPUT VOL so CLIP only blinks on the low frequencies.
Tip: Talkover lowers the music by 30 dB during announcements.
Workflow 2: Restaurant and bar
Dining areas with background music and a host microphone.
Connections
| Connect | To |
|---|---|
| Media player or tablet | LINE input |
| Loudspeakers | HIGH‑Z OUT 70 V or 100 V, or LOW‑Z OUT |
Setup
- Connect the loudspeakers to the matching output.
- Set the bass and treble with a screwdriver.
- Set channel VOL high and OUTPUT VOL to the room level.
Tip: Screwdriver tone controls keep staff from changing the sound by accident.
Workflow 3: Fire alarm muting
Installations that must fall silent on an alarm.
Connections
| Connect | To |
|---|---|
| Fire panel relay (dry contact) | MUTE terminal |
Setup
- Wire the normally open contact to MUTE.
- Trigger a test alarm.
- Check that the MUTE LED lights.
Tip: The MUTE input works with a normally open dry contact.
Workflow 4: Low impedance loudspeakers
Small rooms with a few 4 Ω loudspeakers.
Connections
| Connect | To |
|---|---|
| Loudspeakers, total 4 Ω | LOW‑Z OUT (+, -) |
Setup
- Match the total load to 4 Ω.
- Connect with correct polarity.
- Set the output level.
Tip: Do not use the high and low impedance outputs at the same time.
Workflow 5: Two-zone shop with chime paging
Sites that switch loudspeaker lines on and off by area.
Connections
| Connect | To |
|---|---|
| Zone loudspeaker lines | HIGH‑Z zone outputs |
Setup
- Connect each area to its own zone output.
- Use the front ZONE switches to turn areas on or off.
- Set OUTPUT VOL for the whole system.
Tip: Total power of all zones must not exceed the rated output.
Workflow 6: Energy saving
Venues where the system is often idle.
Connections
| Connect | To |
|---|---|
| Front AUTO switch | Auto standby on |
Setup
- Press the AUTO switch.
- With no input signal the unit enters standby.
- It returns to normal operation as soon as a signal appears.
Tip: Standby consumption is only a few watts.