The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Specifications
Screen
| Size | 10 inch IPS |
| Resolution | 1280 x 800 pixels |
| Active area | 216.58 x 135.36 mm (W x H) |
| Contrast ratio | 1000:1 |
| Brightness | 500 cd/m² |
| Scale | 16:9 |
| Backlight | LED |
| Touch panel | 10 points capacitive |
Control and connectivity
| Processor | Quad‑core, up to 1.8 GHz |
| Ethernet | 1 x RJ45, Cat‑5e or better, 10/100 Mb, 1 Gb auto crossover, PoE |
| Serial port | RS‑232, Euroblock connector |
| Programming and control | Embedded application; compatible with ECLER ENM, EPX, VIDA, HALO, HUB |
| Buttons | Reboot and Factory Reset micro buttons |
Electrical and physical
| Power supply | DC 12 V 2 A and PoE |
| PoE | Class 0, 802.3af PD compliant |
| Max power consumption | 9 W |
| Format | Standard EU single‑gang compatible |
| Installation | In‑wall; desktop with optional accessory |
| Operating temperature | -10 °C to 60 °C |
| Storage temperature | -20 °C to 70 °C |
| Humidity | ≤ 75 % (operating and storage) |
| Dimensions (W x H x D) | 258.84 x 176.54 x 37.2 mm |
| Weight | 0.68 kg |
| Shipping dimensions (W x H x D) | 310 x 63 x 215 mm |
| Shipping weight | 1.08 kg |
| Reference | CPULSO10 |
Product overview
The ECLER PULSO-10 is a 10 inch digital control touch panel compatible with several ECLER product families, with an elegant and discreet design that suits any interior.
Its IPS display (1280 x 800 pixels) and capacitive multitouch surface show fully customised user panels for ECLER VIDA and HALO systems, the HUB series (with the ECLER Pilot application) and EclerNet Manager (hosting UCP panels), and it is ready for the ECLER EclerPLEX ecosystem. The PULSO-10 fits standard European flush-mounted electrical boxes and takes its power over the network cable (PoE), so one Cat-5e cable is all it needs; a web interface handles configuration and maintenance.
| IPS screen, 1280 x 800 pixels | 10 inch |
| Capacitive multitouch | 10 point |
| 802.3af, or 12 V DC 2 A | PoE |
| Maximum power consumption | 9 W |
Key features
- 10 inch IPS screen, 1280 x 800 pixels, LED backlight
- Capacitive multitouch panel with 10 touch points
- Web interface for device configuration and management
- Fully customised user panels
- Compatible with ECLER VIDA, HALO, HUB and EclerNet Manager; ready for EclerPLEX
- PoE powered (802.3af), or from an external 12 V DC 2 A supply
- Standard EU round electrical box compatible, horizontal or vertical mounting
One panel, several ECLER systems
The installer chooses the application the PULSO-10 starts with: EclerPLEX user panels, UCP panels of EclerNet Manager (v6.07r1 onwards, where the panel acts as a WPNETTOUCH), VIDA user panels, PILOT for HUB series zoners, or a web browser mode for web-based graphic user interfaces. After each restart the chosen application opens automatically after a 10 second countdown.
Installed in minutes
The mounting bracket fixes with two screws to a standard European round electrical box (screws 60 mm apart), horizontally or vertically. Connect the network cable, then secure the panel with the security screw. With a PoE switch one cable carries data and power; otherwise any standard 12 V DC 2 A supply connects to the Euroblock plug-in connector. Four rubber feet in the box keep the panel steady on uneven walls.
Easy to manage
Configure the panel on its own Admin page or from a browser on the same network: device name, start-up application, time and NTP synchronisation, DHCP or static addressing, backlight (on, dimmed or off after 15 seconds), brightness and rotation (an accelerometer detects the mounting position), manual or scheduled firmware updates and an event log. The status page even shows a live preview of the panel screen.
In the box
- 1 x PULSO-10 control touch panel
- 4 x rubber feet for in-wall mounting stability
- Security screws
- 1 x First Steps Guide
- 1 x warranty card
Available versions
- PULSO-10: reference CPULSO10
ECLER PULSO-10: frequently asked questions
How is the PULSO-10 powered?
By PoE (802.3af, Class 0) through its RJ45 network connector, or from any standard 12 V DC 2 A supply connected to the DC 12V Euroblock connector. The external supply is not part of the package.
Which ECLER systems can the PULSO-10 control?
The ECLER VIDA and HALO series, the HUB series with the ECLER Pilot application and EclerNet Manager (hosting UCP panels); it is also ready for the ECLER EclerPLEX ecosystem.
What kind of wall box does it need?
A standard European round flush-mounted electrical box (fixing screws 60 mm apart), deep enough for the Ethernet cable and its RJ45 connector.
How do I reset it to factory settings?
Remove the frame, press the Factory Reset micro button on the rear with a pin and confirm on the pop-up that appears. All settings, including the administrator password, return to their defaults.
Where can I buy the ECLER PULSO-10 in India?
The ECLER PULSO-10 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Meeting room control with VIDA
A wall panel for room presets and volume in a corporate meeting room.
Connections
| Connect | To |
|---|---|
| PULSO‑10 | PoE switch port on the VIDA network |
| VIDA user panel | Assigned to a user or created as a public panel |
Setup
- Fix the bracket to the EU round box and connect the network cable.
- Open the Admin page and select the VIDA application.
- Log in with the VIDA user that owns the panel.
- Let the panel restart into the VIDA panel.
Tip: Where several VIDA units share a network, replicate the user panels and users in all of them.
Workflow 2: Restaurant zones with a HUB zoner
Staff control of music source and volume in several zones.
Connections
| Connect | To |
|---|---|
| PULSO‑10 | Network switch shared with the HUB series zoner |
| PILOT application | HUB series user panels |
Setup
- Install the panel next to the bar or reception.
- Select PILOT as the start-up application.
- Link it to the HUB unit on the network.
- Test source and volume changes in each zone.
Tip: With Pilot one panel can control more than one zone of the HUB installation.
Workflow 3: EclerNet Manager UCP panel
A touch panel for a large EclerNet installation in a hotel or venue.
Connections
| Connect | To |
|---|---|
| PULSO‑10 | Network of the EclerNet Manager project |
| UCP application | EclerNet Manager v6.07r1 onwards |
Setup
- Select the UCP application on the panel.
- Turn on the UCP server switch if required.
- Add the panel to the project; it acts as a WPNETTOUCH.
- Load the user control panel and test it.
Tip: Use EclerNet Manager v6.07r1 or later so the project recognises the panel.
Workflow 4: HALO loudspeaker management
Wall control for a HALO based sound system in a gym or shop.
Connections
| Connect | To |
|---|---|
| PULSO‑10 | PoE switch on the HALO network |
Setup
- Mount the panel where staff need it.
- Power it from the PoE switch.
- Choose the application for the HALO system.
- Check the controls the installer prepared.
Tip: Set the backlight to dimmed or off after 15 seconds for energy saving.
Workflow 5: EclerPLEX user panels
Custom control surfaces in the ECLER EclerPLEX ecosystem.
Connections
| Connect | To |
|---|---|
| PULSO‑10 | Network of the EclerPLEX system |
| EclerPLEX application | Panels with an assigned user |
Setup
- Create the graphic panels in EclerPLEX.
- Assign a user to them.
- Select EclerPLEX on the panel.
- Enter the user credentials once (Keep me logged in).
Tip: EclerPLEX panels need a user: assign one before testing.
Workflow 6: Panel powered by a 12 V supply
Installations where the network switch has no PoE.
Connections
| Connect | To |
|---|---|
| 12 V DC 2 A supply | DC 12V Euroblock connector |
| RJ45 | Network switch |
Setup
- Wire the supply to the Euroblock plug, respecting polarity.
- Connect the network cable.
- Secure the panel to the bracket.
- Power up: the panel starts automatically.
Tip: Check polarity before applying power to the DC input.