ECLER SAMI-603
MRP - Rs. 96,900
ECLER SAMI-603 6 x 3 installation mixer, 1 RU: independent routing to three zones, 2 x 3-band tone, talkover, remote MUTE. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Inputs
| Inputs | 4 MIC/LINE, 1 MIC, 1 LINE stereo |
| Connectors | MIC: 3‑pin Euroblock; LINE: RCA |
| Input sensitivity | LINE 2‑5: 0 dB; LINE 6: 0 / -6 dB (internal); MIC 1‑5 balanced: -35 dB |
| Input sensitivity adjust | MIC/LINE: ±15 dB |
| Input impedance | LINE: 50 kΩ; MIC balanced: > 1 kΩ |
| CMRR | MIC: > 60 dB at 1 kHz |
| Phantom voltage | +18 V DC |
Outputs
| Outputs | 1 main mix (stereo or 2 x mono, A/B); 1 main mono (C); 1 AUX/REC (stereo) |
| Connectors | Main: 3‑pin Euroblock; AUX/REC: RCA |
| Nominal output level | OUT: 0 / +6 dB (internal); AUX/REC: 0 / +6 dB (follows MAIN OUT when AUX OUT = POST) |
| Output impedance | OUT: 600 Ω; AUX/REC: 10 kΩ |
Signal and control
| Frequency response | LINE: 10 Hz - 50 kHz; MIC balanced: 10 Hz - 30 kHz (-1 dB) |
| THD + noise | LINE: < 0.005 %; MIC balanced: < 0.04 % |
| Signal to noise ratio | LINE: > 100 dB; MIC balanced: > 85 dB |
| Tone control | 2 x 3‑band (A/B and C): bass 100 Hz, mid 2 kHz, treble 10 kHz, ±15 dB |
| Talkover | Time 2 s, effect -30 dB |
| Controls | Power ON, talkover, LINE/MIC, L+R (input), gain, volume, output destination switches, STEREO / SINGLE, MONO / STEREO |
| Indicators | Power ON LED, MUTE LED, SP/CLIP LEDs |
| Remote control | MUTE control port NO/NC |
Power and physical
| Power supply | ±17.5 V DC external PSU (multi‑plug) |
| AC mains | 100 - 240 V, 50 - 60 Hz |
| Power consumption | 13.9 VA / 6.3 W |
| Cooling | Passive |
| Operating temperature | -10 °C to 40 °C |
| Operating humidity | < 85 % RH |
| Installation | 19 inch rack, 1 RU |
| Dimensions (W x H x D) | 482.5 x 44 x 153.7 mm |
| Weight | 2.0 kg |
| Shipping dimensions (W x H x D) | 560 x 60 x 295 mm |
| Shipping weight | 2.7 kg |
| Reference | CSAMI603 |
Product overview
The ECLER SAMI-603 is an analogue installation mixer in 1 RU rack format with 1 MIC input, 4 MIC/LINE stereo inputs and 1 LINE stereo input, and 3 outputs that can be set as 1 stereo pair plus 1 mono, or 3 independent mono outputs.
Every input channel has a volume control and A, B and C buttons that send it to one or more outputs, so each output gets its own mix: music in one zone, music and announcements in another, paging only in a third. Outputs A/B and output C each have a 3-band tone control. Talkover (priority) can be switched on for inputs 1 to 5 over the output buses, a MUTE input lets a fire detection or safety system silence all three outputs, and +18 V phantom power is available for condenser microphones.
| Inputs x outputs | 6 x 3 |
| Independent routing A, B, C | 3 zones |
| Tone control | 2 x 3‑band |
| Power consumption | 6.3 W |
Key features
- 6 input channels, 3 outputs, 19 inch 1 RU installation mixer
- 4 MIC/LINE stereo inputs, 1 MIC input and 1 LINE stereo input
- Outputs A and B: 1 stereo or 2 mono; output C: mono
- Independent input routing for zones A, B and C
- Independent 3-band EQ for outputs A/B and output C
- Switchable talkover from inputs 1 to 5 over outputs A, B and C
- AUX/REC output, pre or post
- MUTE remote input by dry contact for fire detection and safety systems
- +18 V phantom power for MIC inputs; universal external power supply
Three zones from one mixer
With the STEREO/SINGLE switch in STEREO, OUT A sets the level of A (left) and B (right) together for a stereo zone, with C as a separate mono zone. In SINGLE, A, B and C have their own volume controls for three mono zones. Output C always receives the mono sum of the line inputs assigned to it.
Microphones and line sources
Inputs accept low impedance (200 to 600 Ω) mono microphones on Euroblock with a rear GAIN control, or line sources on RCA with a MONO/STEREO switch. Line input 6 has an internal 0 / -6 dBV sensitivity jumper for media players, tablets and phones.
Priority and safety
Talkover attenuates the non-priority inputs by 30 dB while an announcement is made, returning after 2 seconds. A dry contact on the MUTE terminal silences all three outputs.
In the box
- 1 x SAMI-603 mixer
- 1 x ±17.5 V DC external multi-plug power supply
- Euroblock connectors
- Rubber feet
- Mini jumpers
- 1 x First Steps Guide
- 1 x warranty card
ECLER SAMI-603: frequently asked questions
Can each zone get a different mix?
Yes. Each input has A, B and C buttons to send it to one or more of the three outputs.
Can I use it as three mono zones?
Yes. With the STEREO/SINGLE switch in SINGLE, outputs A, B and C have independent volume controls.
Does it have phantom power?
Yes, +18 V for the MIC inputs, enabled with an internal jumper (off by default).
Can a fire alarm mute it?
Yes. The MUTE input accepts a dry contact closure and silences all three outputs.
Where can I buy the ECLER SAMI-603 in India?
The ECLER SAMI-603 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Retail background music with announcements
Shops that need music and paging from one mixer.
Connections
| Connect | To |
|---|---|
| Paging microphone | MIC input 1 (Euroblock) |
| Media player | LINE input (RCA) |
| Main output (Euroblock) | Power amplifier |
Setup
- Set input 1 to MIC with the rear selector and adjust GAIN.
- Connect the music player to a LINE input.
- Switch on talkover (tk) for the microphone input.
- Set the output volume so the amplifier clip LEDs light only on the strongest bass.
Tip: Talkover lowers the music by 30 dB while the announcement is made.
Workflow 2: Fire alarm muting
Installations that must fall silent when the fire alarm starts.
Connections
| Connect | To |
|---|---|
| Fire detection panel relay (dry contact) | MUTE terminal |
| Main output | Amplifier |
Setup
- Wire the alarm relay contact to the MUTE terminal.
- Trigger a test alarm.
- Check that the MUTE LED lights and the output is silenced.
Tip: The MUTE input works by external dry contact closure (normally open).
Workflow 3: Stereo shop floor plus mono stockroom
A stereo sales area and a mono back-of-house zone.
Connections
| Connect | To |
|---|---|
| OUT A (left) and OUT B (right) | Stereo amplifier |
| OUT C | Mono amplifier |
Setup
- Set the STEREO/SINGLE switch to STEREO.
- Route music to A, B and C and the paging microphone to all outputs.
- Set OUT A for the stereo zone and OUT C for the mono zone.
Tip: In STEREO mode OUT A controls A and B together.
Workflow 4: Classroom or training room
A teacher microphone and a computer or media player.
Connections
| Connect | To |
|---|---|
| Condenser microphone | MIC input (+18 V phantom enabled) |
| Computer | LINE input |
| Main output | Amplifier |
Setup
- Enable phantom power with the internal jumper for condenser microphones.
- Connect the computer to a line input.
- Set levels and enable talkover on the microphone if needed.
Tip: Phantom power is off by default (factory setting).
Workflow 5: Three-zone restaurant
Dining room, bar and terrace with separate levels.
Connections
| Connect | To |
|---|---|
| OUT A / OUT B / OUT C | Three amplifier channels or zone amplifiers |
Setup
- Set the STEREO/SINGLE switch to SINGLE.
- Press the A, B and C buttons of each input to build each zone's mix.
- Set OUT A, OUT B and OUT C volumes and the two tone controls.
Tip: Output C always receives the mono sum of the line inputs assigned to it.
Workflow 6: Recording or second zone feed
Recording meetings or feeding another area.
Connections
| Connect | To |
|---|---|
| AUX/REC output (RCA) | Recorder or second amplifier |
Setup
- Choose AUX PRE or POST with the internal jumper.
- Connect the recorder or second amplifier.
- Check the level.
Tip: In POST mode the AUX/REC level follows the main output setting.