PRICE ON ENQUIRY. For the price, exclusive offers, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share a personalised quotation for Shivansh Electronics, Kolkata, West Bengal, India. All payments are processed securely through Razorpay, our trusted payment gateway partner.
System
| Response (±2 dB) | 31 Hz - 20 kHz |
| -6 dB points | ≤ 29 Hz and 26 kHz |
| Short‑term max. SPL | 130 dB at 1 m |
| Long‑term max. SPL | 124 dB at 1 m |
| Peak SPL per pair | 136 dB at 2 m |
| Self‑generated noise | ≤ 5 dB (A‑weighted, 2 m) |
| Harmonic distortion | At 100 dB SPL: 50‑100 Hz < 1 %, 100 Hz‑3 kHz < 0.5 %, above 3 kHz < 3 % |
Drivers
| Bass | 2 x 380 mm (15 in) cone |
| Midrange | 2 x 125 mm (5 in) cone |
| Treble | Compression driver 50 mm (2 in) into 25 mm (1 in) throat |
RAM-XL amplifier
| Bass amplifier | 2 x 1000 W short term, Class D |
| Midrange amplifier | 2 x 400 W short term, Class D |
| Treble amplifier | 250 W short term, Class D |
| Amplifier THD | < 0.003 % at nominal output |
| S/N (full output) | > 116 dB bass, > 119 dB midrange, > 115 dB treble |
| Mains voltage | 100‑120 V or 220‑240 V AC, 50/60 Hz |
| Power consumption | Standby 6 W, idle 40 W, full output 1000 W long term, 2500 W peak |
Inputs, processing and control
| Analogue input | XLR female, balanced 10 kΩ; maximum +25.0 dBu |
| Analogue sensitivity | -6 dBu for 100 dB SPL at 1 m; input gain 0, +6, +12, +18 dB |
| Digital input | AES/EBU, XLR female 110 Ω; single or dual wire; 16‑24 bit; 32‑192 kHz |
| Digital sensitivity | -30 dBFS for 100 dB SPL at 1 m |
| Digital thru | AES/EBU, XLR male 110 Ω (up to three more SAM monitors or subwoofers) |
| Control network | Proprietary GLM network, 2 x RJ45 (CAT5) |
| GLM adjustment | Notch filters 4 LF and 2 HF; shelving filters 2 LF and 2 HF |
| System calibration | GENELEC GLM AutoCal |
| Crossover | Bass/mid 420 Hz, mid/treble 3.2 kHz |
| Latency | 5.2 ms (analogue input, Extended Phase Linearity off) |
Physical
| Dimensions (H x W x D) | 820 x 1105 x 650 mm |
| Weight | 164 kg enclosure; RAM‑XL amplifier 11.2 kg |
| Amplifier | RAM‑XL, 3U, 483 mm wide, 286 mm deep |
| Colour options | Black |
Product overview
The GENELEC 1235A brings the sound and heritage of the iconic GENELEC 1035 into the modern recording age: high SPL capability and precise imaging in a main monitor that adapts to your room.
Two 380 mm woofers, two 130 mm midrange drivers and a 50 mm compression driver into a 25 mm throat work with 96 kHz processing and Smart Active Monitoring. The rotatable DCW allows horizontal or vertical mounting, and the outstanding on- and off-axis response gives a very wide, stable sweet spot that several listeners can trust. The RAM-XL rack amplifier delivers 2 x 1000 W, 2 x 400 W and 250 W.
| Short‑term max. SPL at 1 m | 130 dB |
| Frequency response (-6 dB) | 29 Hz - 26 kHz |
| RAM‑XL amplifier power | 3,050 W |
| Enclosure weight | 164 kg |
Key features
- Heritage of the 1035 with 96 kHz processing and Smart Active Monitoring
- Drivers: 2 x 380 mm woofers, 2 x 130 mm midranges, 50 mm compression tweeter
- Rotatable DCW (±90°) for horizontal or vertical mounting
- 130 dB short-term SPL at 1 m; peak 136 dB per pair at 2 m
- 31 Hz - 20 kHz (±2 dB) response
- RAM-XL amplifier: 2 x 1000 W + 2 x 400 W + 250 W
- Analogue and AES/EBU inputs (up to 192 kHz) with AES/EBU thru
- GLM calibration with AutoCal, room compensation and level and delay alignment
Classic heritage
The original 1035 became the hallmark of prestigious studios that needed a wall-mountable full-range monitor with true reference performance at high SPL and long listening distances.
Cutting-edge performance
Superb directivity gives a very wide and stable sweet spot, and GLM configures, controls and calibrates the 1235A for any acoustic environment.
Remote RAM-XL amplifier
The individually calibrated RAM-XL is a 19-inch 3U rack unit with fan cooling; 10 m Speakon and RJ45 cables are included for the link to the enclosure with the same serial number.
In the box
- GENELEC 1235A monitor
- Individually calibrated RAM-XL amplifier unit
- Mains cable (1.8 m)
- RJ45 cable (5 m)
- RJ45 cable (10 m)
- 2 x four-pole Speakon cables (10 m)
- Allen key (for the DCW plate)
- Operating manual
GLM calibration uses the free GLM software with the GENELEC 9320A SAM Reference Controller or the GLM Calibration Kit (each available separately).
GENELEC 1235A: frequently asked questions
Is this the complete monitor?
Yes. This is the GENELEC 1235A complete monitor (part 1235AP): enclosure, individually calibrated RAM-XL amplifier and cables.
Can it be mounted horizontally?
Yes. The DCW rotates through ±90° for horizontal or vertical mounting.
What do I need for GLM calibration?
The free GLM software and a GENELEC 9320A SAM Reference Controller or GLM Calibration Kit (each available separately).
Where can I buy the GENELEC 1235A in India?
The GENELEC 1235A is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Stereo main monitoring with GLM calibration
Set up a pair of 1235A monitors as the calibrated reference of a control room.
Connections
| Connect | To |
|---|---|
| Console or monitor controller outputs | ANALOG IN (XLR) or DIGITAL IN AES/EBU |
| GLM adapter (9320A or GLM Calibration Kit) | CONTROL NETWORK (RJ45) |
| Computer with GLM | GLM adapter, USB |
| Mains | MAINS INPUT, earthed outlet |
Setup
- Place the monitors symmetrically with their acoustic axes aimed at the listening position.
- Link the RAM-XL to its own enclosure (same serial number) with the two Speakon cables and the RJ45 LED cable.
- Daisy-chain the CONTROL NETWORK sockets and end at the GLM adapter; place the measurement microphone at ear height.
- Run GLM AutoCal, then store the settings in the monitors.
Tip: Keep the AES/EBU source level near 0 dBFS and lower the GLM level instead, to keep full digital resolution.
Workflow 2: Flush mounting in the front wall
Build the monitors into the wall to avoid edge diffraction and wall reflections.
Connections
| Connect | To |
|---|---|
| Monitor enclosure | Wall opening with 50‑100 mm clearance |
| Vibration isolators | Under the enclosure (2‑8 Hz resonance) in light walls |
| Facing panel and gasket | Front of the wall, 5‑10 mm soft rubber gap |
Setup
- Make the wall stiff and heavy and angle it so the monitors aim at the listener (tilt under 15 degrees).
- Rotate the DCW so the midrange and tweeter align vertically (eight M5 screws, 4 mm Allen key).
- Fit the facing panel flush with the enclosure and fill the gap with a soft rubber gasket.
- Keep any cloth frame under 20 mm deep and acoustically transparent.
Tip: Plan the cable recess behind the enclosure: the Speakon connectors need about 100 mm.
Workflow 3: Machine room amplifiers
Keep amplifier heat and fan noise out of the control room.
Connections
| Connect | To |
|---|---|
| RAM‑XL amplifier | 19‑inch rack, 3U |
| Enclosure | WOOFER and MIDRANGE/TWEETER Speakon, LED CONNECTOR RJ45 |
| GLM network | CONTROL NETWORK, in any order in the chain |
Setup
- Mount each amplifier in the rack with free air around it (RAM-XL: 100 mm free behind).
- Run the 10 m Speakon and RJ45 cables; for longer runs use 2.0 mm² up to 30 m, 3.3 mm² up to 40 m, 5.3 mm² up to 60 m.
- Turn each Speakon connector clockwise until it locks.
- Network the amplifiers last in the GLM chain if they are in the machine room.
Tip: Never mix amplifier and enclosure pairs: each amplifier is calibrated for its own enclosure.
Workflow 4: Surround and immersive systems
Use the monitors as the main channels of a 5.1 or immersive system.
Connections
| Connect | To |
|---|---|
| 1235A monitors | Main channels on the GLM network |
| GENELEC SAM subwoofers and monitors | Same GLM network |
| AES/EBU source | DIGITAL IN, with DIGITAL THRU to the next monitor |
Setup
- Place the monitors according to ITU-R BS.775-1 for 5-channel work.
- Assign each monitor's AES/EBU subframe (A or B) in GLM.
- Measure all monitors and subwoofers together with GLM.
- Store the settings or keep the computer connected for control.
Tip: One AES/EBU line can feed up to four SAM units through the DIGITAL THRU connectors.
Workflow 5: Broadcast and post production without a computer
Run calibrated monitors in a facility where no computer stays connected.
Connections
| Connect | To |
|---|---|
| AES/EBU or analogue feed | DIGITAL IN or ANALOG IN |
| Mains | MAINS INPUT |
Setup
- Calibrate the system with GLM.
- Use Store the Settings to write the setup into the monitors.
- Disconnect the computer; the monitors keep their calibration.
- Switch on ISS in GLM if the monitors should go to standby when idle.
Tip: Watch the front light: red means overload or an AES/EBU data error; turn the source down.
Workflow 6: Mastering and critical listening
Make final decisions on a neutral, low-distortion reference.
Connections
| Connect | To |
|---|---|
| Mastering chain output | DIGITAL IN AES/EBU (up to 192 kHz) or ANALOG IN |
| GLM network | CONTROL NETWORK |
Setup
- Place the monitors symmetrically at equal distance from the listening position.
- Calibrate with GLM and check the level alignment.
- Set the input sensitivity in GLM for a comfortable working level.
- Keep symmetrical reflective surfaces around the listening position.
Tip: These monitors can exceed 85 dB SPL: protect your hearing in long sessions.