KASPER D-2600.2
PRICE ON ENQUIRY
KASPER D-2600.2 two-channel Class D power amplifier, 2 x 600 W RMS at 8 Ω, 2 x 900 W at 4 Ω, 1U, XLR inputs. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
PRICE ON ENQUIRY. For the price, exclusive offers, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share a personalised quotation for Shivansh Electronics, Kolkata, West Bengal, India. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Specifications
| Size | 1U |
| Number of output channels | 2 |
| Output connection type | Twist‑lock loudspeaker connectors |
| Output configuration | 2 x 600 W RMS at 8 Ω |
| Maximum output power | 2 x 900 W at 4 Ω |
| Frequency response | 20 Hz - 25 kHz (-1 dB, -3 dB) |
| Input impedance | 20 kΩ (balanced) / 10 kΩ (unbalanced) |
| Damping factor | Above 500:1 |
| THD + noise | Below 0.1 % at 1 kHz, full power |
| Signal‑to‑noise ratio | Above 85 dB, 20 Hz - 20 kHz at 1 W / 4 Ω |
Power and physical
| AC mains requirement | 100‑240 V, 50‑60 Hz |
| AC mains connector | AC socket connector (IEC) |
| Dimensions | 430 x 160 x 590 mm |
| Shipping weight | 4.6 kg |
Product overview
The KASPER D-2600.2 is a compact yet powerful two-channel Class D power amplifier: 2 x 600 W RMS at 8 Ω and 2 x 900 W at 4 Ω in a 1U metal chassis.
Built with advanced Class D technology, the D-2600.2 delivers high efficiency, stable output and reliable operation for demanding installations. XLR inputs, twist-lock loudspeaker outputs, a built-in cooling fan, LED status indicators and a universal 100-240 V mains supply make it a natural choice for professional audio setups, commercial spaces, events and auditoriums.
| RMS at 8 Ω | 2 x 600 W |
| Maximum at 4 Ω | 2 x 900 W |
| Frequency response | 20 Hz - 25 kHz |
| Rack size | 1U |
Key features
- Class D two-channel power amplifier
- 2 x 600 W RMS at 8 Ω, 2 x 900 W at 4 Ω
- Stereo output configuration
- Built-in cooling fan
- LED status indicators
- Low noise and stable performance: SNR above 85 dB
- Durable metal construction, compact and lightweight
- Universal mains voltage 100-240 V, 50-60 Hz
Clean, efficient power
Frequency response is 20 Hz - 25 kHz (-1 dB, -3 dB), the damping factor exceeds 500:1 and THD + noise stays below 0.1 % at 1 kHz at full power.
Connections
Each channel has an XLR input and an XLR link socket. The loudspeakers connect to twist-lock outputs (CH.A and CH.B), and a DIP switch block on the rear carries the panel markings ST, BR/PAL, 1V and 0.775V.
Front panel
Two level controls (CHA and CHB, scale -∞ to 0 dB) with LED indicators for PROT, CLIP, -3 dB, -6 dB, -12 dB, -24 dB, signal and ON sit between the ventilation grilles, with the power switch on the right.
In the box
- D-2600.2 power amplifier
KASPER D-2600.2: frequently asked questions
How much power does the D-2600.2 deliver?
2 x 600 W RMS at 8 Ω, and 2 x 900 W maximum at 4 Ω.
Which inputs does it have?
An XLR input and an XLR link socket for each of the two channels; input impedance 20 kΩ balanced, 10 kΩ unbalanced.
What mains voltage does it accept?
100-240 V at 50-60 Hz (AC socket connector, IEC).
How big is it?
A 1U chassis, 430 x 160 x 590 mm, with a shipping weight of 4.6 kg.
Where can I buy the KASPER D-2600.2 in India?
The KASPER D-2600.2 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Loudspeakers in a commercial space
Loudspeakers for a shop, showroom or hall.
Connections
| Connect | To |
|---|---|
| Mixer or processor outputs | INPUT CH.A / CH.B (XLR) |
| Loudspeakers | OUTPUT CH.A / CH.B |
Setup
- Connect the source outputs to the XLR inputs.
- Connect the loudspeakers to the channel outputs.
- Switch on and raise the level controls.
Tip: 2 x 600 W RMS at 8 Ω.
Workflow 2: Events
Main loudspeakers for an event.
Connections
| Connect | To |
|---|---|
| Mixer outputs | XLR inputs |
| Loudspeakers (4 Ω or 8 Ω) | Twist‑lock outputs |
Setup
- Connect the mixer to the inputs.
- Connect the loudspeakers.
- Set the levels while watching the LED indicators.
Tip: Up to 2 x 900 W at 4 Ω.
Workflow 3: Auditorium
Speech and programme reinforcement.
Connections
| Connect | To |
|---|---|
| Processor or mixer | XLR inputs |
| Auditorium loudspeakers | Twist‑lock outputs |
Setup
- Connect the processor outputs.
- Connect the loudspeakers.
- Set each channel's level.
Tip: Frequency response 20 Hz - 25 kHz.
Workflow 4: Professional audio setup
A rack-mounted amplifier for a fixed installation.
Connections
| Connect | To |
|---|---|
| System processor | XLR inputs |
| Installed loudspeakers | Twist‑lock outputs |
Setup
- Install the 1U unit.
- Connect the inputs and loudspeakers.
- Power on and set the levels.
Tip: The built-in cooling fan keeps the amplifier cool.
Workflow 5: Commercial spaces with several areas
Separate loudspeakers for different areas of a venue.
Connections
| Connect | To |
|---|---|
| Processor outputs per area | One XLR input per channel |
| Area loudspeakers | One output per channel |
Setup
- Give each area its own channel.
- Connect the loudspeakers of each area.
- Set each channel's level for its area.
Tip: Each channel has its own level control on the front.
Workflow 6: Installations on different mains supplies
Sites with 100-240 V mains.
Connections
| Connect | To |
|---|---|
| Mains | AC mains connection |
Setup
- Connect the mains supply.
- Switch on with the front power switch.
- Check the LED indicators.
Tip: Universal voltage: 100-240 V, 50-60 Hz.