SENNHEISER MD 445
MRP - Rs. 45,000
SENNHEISER MD 445: Dynamic Microphone. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is inclusive of all taxes. Contact / WhatsApp +91 89818 07755 / +91 91477 00677 to check if any offers or additional discounts are available. If available, we will gladly share a coupon code that you can apply at checkout for the best price. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Product Features
| On/off switch | No |
Product
| Transducer type | Dynamic |
Frequency Specifications
| Audio frequency response | 40 - 20,000 Hz |
Acoustic Properties
| Pickup pattern | Supercardioid |
Connectivity
| Connection | Wired |
| Connectors | 3-pin XLR |
Electrical Properties
| Sensitivity in free field, no load (1kHz) | 1,6 mV/Pa |
| Nominal impedance | 245 Ω |
| Min. terminating impedance | 1000 Ω |
Dimensions
| Dimensions | Ø 47.5 x 174 mm |
| Product weight | 329 g |
| Product diameter | 47.5 mm |
Product overview
The SENNHEISER MD 445 is a dynamic microphone from SENNHEISER, part of the Md Series range.
MD 445
Closer. More direct. More intense.\t
\t
The MD 445 pushes the potential of dynamic microphones to the limits of what is technically viable. The direct, focused sound gives every voice greater presence and intensity. Its sophisticated transparency and the richness of the low and middle ranges create an unparalleled acoustic closeness.
Time and effort have gone into newly tailoring the acoustics of the MD 445 for modern stages and the most demanding of live productions. An all new highly developed aluminum-copper voice coil forms the basis for a noticeably direct and nuanced sound.
| Pickup pattern | Supercardioid |
| Transducer type | Dynamic |
| Audio frequency response | 40 - 20,000 Hz |
| Sensitivity in free field, no load (1kHz) | 1,6 mV/Pa |
Key features
- Dynamic vocal microphone
- Very lightweight, rapidly responding aluminum- copper voice coil
- High-resolution, direct sound for audibly greater proximity to the vocals
- Directionality: high-rejection supercardioid
- Extremely high feedback resistance
- Large diaphragm diameter
- Spring-mounted capsule to shield it from body-borne noise
- Hum compensation coil to eliminate electromagnetic interference
- Rugged metal design
SENNHEISER MD 445: frequently asked questions
What is the pickup pattern of the MD 445?
Supercardioid, according to the official specification.
What is the frequency response of the MD 445?
40 - 20,000 Hz.
Which connector does the MD 445 use?
3-pin XLR.
Where can I buy the SENNHEISER MD 445 in India?
The SENNHEISER MD 445 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Lead vocals on stage
Singers and front-of-house engineers at concerts and events.
Connections
| Connect | To |
|---|---|
| MD 445 output (3-pin XLR) | Microphone input of the mixer, interface or recorder |
Setup
- Mount the MD 445 on a stand with its clip, at mouth height.
- No phantom power is needed for a dynamic microphone; leave it off unless other devices on the line need it.
- Set the input gain while the singer performs at full level.
- Place stage monitors in the null of the supercardioid pickup pattern to keep feedback down.
Workflow 2: Backing vocals
Bands with several singers sharing one stage.
Connections
| Connect | To |
|---|---|
| MD 445 output (3-pin XLR) | Microphone input of the mixer, interface or recorder |
Setup
- Give each backing singer their own MD 445.
- Keep a similar distance to the microphone for every singer so the levels stay even.
- Use a high-pass filter on the mixer channel to clean up stage rumble.
Workflow 3: Speech and presentations
Conference halls, schools, places of worship and events.
Connections
| Connect | To |
|---|---|
| MD 445 output (3-pin XLR) | Microphone input of the mixer, interface or recorder |
Setup
- Hand the MD 445 to the presenter or mount it on a stand at the lectern.
- No phantom power is needed for a dynamic microphone; leave it off unless other devices on the line need it.
- Set the gain for a normal speaking voice a hand's width from the microphone.
Workflow 4: Recording at home or in the studio
Home studios and project studios.
Connections
| Connect | To |
|---|---|
| MD 445 output | Microphone input of an audio interface |
Setup
- Connect the MD 445 to an audio interface with a balanced microphone cable.
- No phantom power is needed for a dynamic microphone; leave it off unless other devices on the line need it.
- Set the gain so the loudest parts peak well below clipping.
Workflow 5: Podcasts and streaming
Podcasters and content creators.
Connections
| Connect | To |
|---|---|
| MD 445 output | Audio interface or mixer microphone input |
Setup
- Mount the MD 445 on a desk stand or boom arm.
- Speak from a constant distance for an even level.
- Monitor on headphones while recording.
Workflow 6: Live events and rentals
Rental companies and event sound teams.
Setup
- Check the MD 445 and its cable before each event.
- Label microphones and cables per channel for quick changeovers.
- Store the microphone in its pouch or case after use.