ECLER ALMA26
MRP - Rs. 1,58,900
ECLER ALMA26 2 in / 6 out digital loudspeaker manager: LCD and encoder, crossovers, EQ, delay, limiters, 6 templates, USB, 1 RU. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Audio
| Inputs | 2, XLR3 female, balanced, 0 dBV |
| Input impedance | Above 20 kΩ, electronically balanced |
| CMRR | Above 55 dB (20 Hz - 20 kHz) |
| Outputs | 6, XLR3 male, balanced, 0 dBV nominal |
| Output impedance | 300 Ω, electronically balanced |
| A/D and D/A | 24 bit / 48 kHz |
| Frequency response | Below 10 Hz - 20 kHz |
| Output noise floor (FFT) | Below -115 dB (20 Hz - 20 kHz) |
| THD + noise | Below 0.0028 % (1 kHz, 1 Vrms) |
| Crosstalk | Above 95 dB, 30 Hz - 20 kHz |
Processing
| Crossover types | Linkwitz‑Riley, Butterworth, Bessel |
| Crossover slopes | 6, 12, 18, 24 or 48 dB/oct (type dependent) |
| Input / output delay | 1 s, 20.8 µs steps |
| EQ quantity | 4 per input, 8 per output |
| EQ types | Parametric (Q 0.3 to 200); low and high shelf 6/12 dB/oct; low and high pass 6/12 dB/oct; all pass |
| EQ gain / frequency | -60 to +12 dB in 0.1 dB steps / 20 Hz - 20 kHz |
| Compressor threshold | -36 to +12 dBV |
| Attack / release | 0.1 - 500 ms / 1 ms - 5 s |
| Ratio | 1:1 to ∞:1 |
Control, electrical and physical
| Front panel | 2 x 20 LCD, encoder, 4 setup keys, 8 MUTE keys, level meters |
| Control | USB type B, EclerCOMM Manager |
| Remote controls | 2 x 0‑10 V DC, Euroblock |
| Mains | 100‑240 V AC, 47‑63 Hz, IEC socket |
| Power consumption | 25 VA |
| Operating temperature | -10 °C to 40 °C |
| Installation | 19 inch rack (1 RU) |
| Dimensions (W x H x D) | 482.6 x 44 x 120 mm |
| Weight | 1.75 kg |
| Shipping dimensions (W x H x D) | 560 x 60 x 220 mm |
| Shipping weight | 2.6 kg |
Product overview
The ECLER ALMA26 is a 1 RU digital loudspeaker manager with 2 balanced inputs, 6 balanced outputs, 24 bit / 48 kHz DSP, a front panel LCD with encoder, a USB interface and 2 volume remote control ports (0-10 V DC).
It manages stereo 3-way systems, stereo 2-way systems with subwoofers or up to six mono outputs. Every channel has gain, mute, polarity, parametric EQ and delay, and the outputs add crossover filters and a compressor / limiter. Settings are made from the front panel, with a 2 x 20 character display, push encoder, 4 setup keys and a backlit MUTE key with level meter for each input and output, or from the free EclerCOMM Manager application over USB.
| Balanced XLR inputs and outputs | 2 x 6 |
| DSP processing | 24 bit / 48 kHz |
| System templates | 6 |
| User presets | 20 |
Key features
- 2 inputs x 6 outputs, all balanced on XLR
- Front panel control: 2 x 20 LCD, encoder, 4 setup keys, 8 MUTE keys and level meters
- Crossovers: Butterworth, Linkwitz-Riley or Bessel on the outputs, up to 48 dB/oct
- Parametric EQ: 4 per input, 8 per output
- Delays on inputs and outputs, up to 1 s
- Output compressor / limiter with make-up gain; 3 LINK groups
- 6 system templates, 20 user presets, editable labels, 2 password lock modes
- USB with EclerCOMM Manager; 2 x 0-10 V DC remote ports
Six templates
T1 3 x 1 stereo way, T2 2 stereo ways + 1 stereo way, T3 3 stereo ways, T4 4 mono ways + 2 mono auxiliaries, T5 5 mono ways + 1 mono auxiliary and T6 6 mono outputs. Each template sets the channel modes and LINK groups, so a change on one side of a stereo pair is copied to the other.
Front panel or computer
MENU and PARAM keys move through pages and parameters, the encoder edits values, and SHIFT combinations recall, save and rename presets. Two lock modes protect the set-up: full lock, or lock that leaves the MUTE keys free.
Remote volume control
REMOTE A and B control the volume of chosen inputs or outputs from WPa series wall panels, assigned from the front panel menu or from EclerCOMM Manager.
In the box
- 1 x ALMA26
ECLER ALMA26: frequently asked questions
Can it run a stereo 3-way system?
Yes. Template T3 sets up 3 stereo ways on the 6 outputs.
Do I need a computer?
No. All settings are available from the front panel; EclerCOMM Manager over USB is an alternative.
Can the front panel be locked?
Yes, with a password, either fully or leaving the MUTE keys available.
How is it powered?
From 100-240 V AC, 47-63 Hz, through an IEC socket, with a consumption of 25 VA.
Where can I buy the ECLER ALMA26 in India?
The ECLER ALMA26 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Stereo 3-way system
Installations with 3-way loudspeakers.
Connections
| Connect | To |
|---|---|
| Mixer L/R | INPUT 1‑2 |
| OUTPUT 1‑6 | Low, mid and high amplifiers |
Setup
- Recall template T3.
- Set crossover points and slopes.
- Align the ways with delay.
- Set output limiters and save a preset.
Tip: LINK groups keep both sides identical.
Workflow 2: 2-way stereo plus subwoofers
Clubs and bars.
Connections
| Connect | To |
|---|---|
| Mixer L/R | INPUT 1‑2 |
| OUTPUT 1‑4 | Tops |
| OUTPUT 5‑6 | Subwoofers |
Setup
- Recall template T2.
- Set the subwoofer crossover.
- Set EQ for the room.
- Save and rename the preset.
Tip: Hold the right MENU key at power-up to load preset 1.
Workflow 3: Six monitor mixes
Live sound stages.
Connections
| Connect | To |
|---|---|
| Monitor sends | INPUT 1‑2 |
| OUTPUT 1‑6 | Monitor amplifiers |
Setup
- Recall template T6.
- Notch feedback frequencies.
- Set limiters.
- Use the MUTE keys during line checks.
Tip: Lock the panel but leave the MUTE keys free.
Workflow 4: Zone outputs with delay
Halls with delayed loudspeakers.
Connections
| Connect | To |
|---|---|
| Programme | INPUT 1 |
| OUTPUT 1‑6 | Zone amplifiers |
Setup
- Assign outputs to zones.
- Set delay per zone.
- Match levels.
- Lock the front panel.
Tip: Delay reaches 1 s per output.
Workflow 5: Wall panel volume
Venues where staff adjust the level.
Connections
| Connect | To |
|---|---|
| WPa panel | REMOTE A |
| ALMA26 | Outputs |
Setup
- Wire the panel to REMOTE A.
- Assign it in the setup menu.
- Save the preset.
- Test the range.
Tip: REMOTE B can control a different group.
Workflow 6: Computer set-up and backup
Integrators.
Connections
| Connect | To |
|---|---|
| Computer | USB |
| ALMA26 | Amplifier rack |
Setup
- Connect with EclerCOMM Manager.
- Tune and send the configuration.
- Save the file on the computer.
- Set the password.
Tip: Keep a file copy of every finished system.