The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
System
| Effective frequency range | 115 Hz - 17 kHz (-10 dB) |
| Coverage angle | 157° x 157° (H x V) |
| Power handling | 6 W RMS / 24 W peak |
| Sensitivity (1 W / 1 m) | 91 dB |
| Maximum SPL | 99 dB continuous / 105 dB peak |
| Power options | 100 V: 3 / 6 W; 70 V: 1.5 / 3 W |
| Recommended amplifier | 12 W |
Transducer
| Ways | 1‑way, full range |
| Driver | 4.5 inch woofer, ferrite magnet, paper cone |
| Nominal impedance | 8 Ω |
Physical
| Connection | Screw terminals |
| Power selection | Colour code connection (rear) |
| Installation | In‑ceiling, in‑wall |
| Environmental | IP50 |
| Enclosure | ABS plastic |
| Grille | Powder coated iron |
| Mounting | Spring clamps |
| Colour | White (RAL 9016) |
| External diameter | 160 mm |
| Cut‑out diameter | 145 mm |
| Required depth | > 54 mm |
| Ceiling thickness | Up to 55 mm |
| Weight | 0.5 kg |
| Shipping | 178 x 178 x 63 mm, 0.75 kg, 1 per box |
| Reference | CEIC51FM |
Product overview
The ECLER eIC51FM is a cost-effective 4.5 inch in-ceiling installation loudspeaker with a fast-mounting system that needs no tools or additional fixings, and a 70 / 100 V line transformer with 3 and 6 W power options.
Spring clamps hold it in a 145 mm cut-out in seconds. The one-way, full-range 4.5 inch woofer delivers 91 dB sensitivity and 157° coverage, the ABS plastic basket carries a borderless powder coated iron grille in white (RAL 9016), and the IP50 rating suits indoor installations. Power taps are selected by the colour-coded wires on the rear.
| 24 W peak | 6 W RMS |
| 100 V taps | 3 / 6 W |
| Sensitivity (1 W / 1 m) | 91 dB |
| Coverage | 157° |
Key features
- Easy and fast mounting with spring clamps
- 4.5 inch woofer, one-way full range
- 6 W RMS / 24 W peak
- 100 V: 3 / 6 W; 70 V: 1.5 / 3 W; 8 Ω connection
- Screw terminals
- IP50 rated
- White RAL 9016, powder coated iron grille
- Acoustic simulation data files available
Fast mounting
Cut a 145 mm hole, connect the line and push the loudspeaker in: the two spring clamps fix it to ceilings up to 55 mm thick.
Line or low impedance
The transformer offers 3 and 6 W on 100 V lines, 1.5 and 3 W on 70 V lines, plus an 8 Ω connection.
Even coverage
157° coverage and an effective range of 115 Hz to 17 kHz suit shops, offices, gyms and leisure areas.
In the box
- 1 x eIC51FM loudspeaker (1 unit per box)
ECLER eIC51FM: frequently asked questions
Does it need tools to mount?
No. Spring clamps hold it in the ceiling without tools or extra fixings.
Which taps are available?
3 and 6 W on 100 V lines, 1.5 and 3 W on 70 V lines, and 8 Ω.
What cut-out size is needed?
145 mm, with more than 54 mm depth.
Is it suitable for humid areas?
It is IP50 rated for indoor installation.
Where can I buy the ECLER eIC51FM in India?
The ECLER eIC51FM is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Shop ceiling music
Retail sales floors on a 100 V line.
Connections
| Connect | To |
|---|---|
| 100 V amplifier output | eIC51FM line input |
Setup
- Plan one loudspeaker per area.
- Choose the 3 W or 6 W tap for the level needed.
- Respect polarity along the line.
Tip: Add the tap powers of all speakers to size the amplifier.
Workflow 2: Restaurant and café
Even background music at moderate level.
Connections
| Connect | To |
|---|---|
| Mixing amplifier HIGH‑Z OUT | Loudspeaker line |
Setup
- Use the lower tap near seating.
- Use the higher tap in busy areas.
- Set the amplifier level.
Tip: On 70 V lines the tap powers are halved.
Workflow 3: Office and corridor paging
Announcements across offices and corridors.
Connections
| Connect | To |
|---|---|
| Paging amplifier | Loudspeaker line |
Setup
- Install loudspeakers at regular spacing.
- Connect all on one line.
- Test announcements from each area.
Tip: Wide coverage helps intelligibility.
Workflow 4: Gym and wellness centre
Music in changing rooms and studios.
Connections
| Connect | To |
|---|---|
| Zone amplifier | Loudspeaker line per zone |
Setup
- Group loudspeakers by zone.
- Choose taps per room.
- Balance levels per zone.
Tip: Keep separate lines for zones that need different volumes.
Workflow 5: Meeting room
Voice and background music in small rooms.
Connections
| Connect | To |
|---|---|
| Mixer amplifier | Loudspeakers |
Setup
- Fit two or more loudspeakers in the ceiling.
- Select the tap.
- Adjust the mixer tone controls.
Tip: Use acoustic simulation data files to plan coverage.
Workflow 6: Retrofit in an existing ceiling
Replacing older ceiling loudspeakers.
Connections
| Connect | To |
|---|---|
| Existing 100 V line | New loudspeaker |
Setup
- Check the cut-out size.
- Connect the existing wires.
- Fix the speaker and refit the grille.