ECLER eIC52MS
MRP - Rs. 14,900
ECLER eIC52MS two-way 5 inch marine / sauna in-ceiling loudspeaker, 20 W RMS, IP54, for high humidity. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
System
| Effective frequency range | 83 Hz - 20 kHz (-10 dB) |
| Coverage angle | 155° x 155° (H x V) |
| Power handling | 20 W RMS / 80 W peak |
| Sensitivity (1 W / 1 m) | 91 dB |
| Maximum SPL | 104 dB continuous / 110 dB peak |
| Recommended amplifier power | 40 W RMS |
Transducers
| Ways | 2 |
| Low frequency driver | 5 inch woofer |
| High frequency driver | 1 inch tweeter |
| Nominal impedance | 8 Ω |
Physical
| Connection | Faston male input terminals: 4.8 mm (+) and 2.8 mm (-) |
| Installation | In‑ceiling, in‑wall |
| Environmental | IP54 rated |
| Grille fixing system | 4 x screw fixing system |
| External diameter | 165 mm |
| Internal diameter | 120 mm |
| Recommended cut‑out diameter | 125 mm |
| Required depth | 79 mm |
| Operating temperature | -25 °C to 70 °C |
| Operating humidity | Below 90‑95 % RH |
| Colour | White (RAL 9016) |
| Weight | 0.70 kg |
| Shipping dimensions (W x H x D) | 210 x 80 x 210 mm |
| Shipping weight | 1.2 kg |
| Pieces per box | 1 |
Product overview
The ECLER eIC52MS is a two-way marine / sauna in-ceiling loudspeaker for installations exposed to extreme humidity and/or temperature, with a 5 inch woofer, a 1 inch tweeter and 20 W RMS at 8 Ω.
IP54 rated and working from -25 °C to 70 °C with up to 90-95 % relative humidity, the eIC52MS brings music and announcements to saunas, spas, aquariums, ships and harbours. It connects with Faston male terminals (4.8 mm + and 2.8 mm -), fits a 125 mm cut-out with 79 mm of depth, and its white (RAL 9016) grille is held by four screws.
| At 8 Ω, 80 W peak | 20 W RMS |
| Humidity proof | IP54 |
| Sensitivity (1 W / 1 m) | 91 dB |
| Coverage angle | 155° |
Key features
- Two-way speaker: 5 inch woofer and 1 inch tweeter
- 20 W RMS at 8 Ω, 80 W peak
- Faston male input terminals: 4.8 mm (+) and 2.8 mm (-)
- Suitable for extreme humidity and/or temperature: IP54, -25 °C to 70 °C
- Four-screw grille fixing
- In-ceiling or in-wall; acoustic simulation data files available
Built for wet and hot spaces
The IP54 rating and an operating range from -25 °C to 70 °C at up to 90-95 % relative humidity make the eIC52MS suitable for saunas, spas and marine use.
Clear two-way sound
A 5 inch woofer and a 1 inch tweeter cover 83 Hz to 20 kHz (-10 dB) with 91 dB sensitivity and 155° coverage, reaching 104 dB continuous and 110 dB peak.
Easy installation
The speaker needs a 125 mm cut-out and 79 mm of depth. Faston terminals take the cable and four screws fix the white RAL 9016 grille.
In the box
- 1 x eIC52MS in-ceiling loudspeaker
ECLER eIC52MS: frequently asked questions
Can the eIC52MS be used in a sauna?
Yes. ECLER designed it for installations exposed to extreme humidity and/or temperature, including saunas and spas.
What amplifier does it need?
The eIC52MS is an 8 Ω loudspeaker; ECLER recommends an amplifier of 40 W RMS.
What cut-out does it need?
A 125 mm cut-out and 79 mm of installation depth; the external diameter is 165 mm.
How is it connected?
With Faston male input terminals: 4.8 mm for (+) and 2.8 mm for (-).
Where can I buy the ECLER eIC52MS in India?
The ECLER eIC52MS is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Sauna
Music in a sauna cabin exposed to heat and humidity.
Connections
| Connect | To |
|---|---|
| 8 Ω amplifier output (outside the cabin) | Faston terminals |
| Speaker cable | 4.8 mm (+) / 2.8 mm (-) |
Setup
- Cut a 125 mm hole in the ceiling; allow 79 mm of depth.
- Connect the cable to the Faston terminals, respecting polarity.
- Fit the speaker and fix the grille with its four screws.
- Set a comfortable level from the amplifier outside.
Tip: The speaker operates from -25 °C to 70 °C and up to 90-95 % relative humidity.
Workflow 2: Spa and wellness area
Relaxing background music in humid treatment rooms and pool areas.
Connections
| Connect | To |
|---|---|
| Low‑impedance amplifier | Speaker Faston terminals |
| Second speaker | Separate output or channel |
Setup
- Plan one speaker per treatment room or zone.
- Install in the ceiling or wall with a 125 mm cut-out.
- Wire each speaker to the amplifier output.
- Balance the levels between rooms.
Tip: Allow about 40 W RMS of amplifier power per speaker, as ECLER recommends.
Workflow 3: Ships
Cabins and onboard spaces exposed to sea air and humidity.
Connections
| Connect | To |
|---|---|
| Amplifier output | Faston terminals |
| Cable | Through the ceiling panel |
Setup
- Choose the speaker positions in the cabin ceiling.
- Cut the 125 mm openings.
- Connect, fit and screw the grilles.
- Test each cabin.
Tip: The IP54 rating protects the speaker against dust and water splashes.
Workflow 4: Harbour buildings
Announcements and music in harbour offices and waiting areas.
Connections
| Connect | To |
|---|---|
| Amplifier output | Speakers in each area |
| Source | Amplifier input |
Setup
- Install the speakers in the ceiling of each area.
- Wire them to the amplifier outputs.
- Set the levels for clear announcements.
- Check coverage across the room.
Tip: 155° coverage spreads the sound widely below each speaker.
Workflow 5: Aquarium
Background sound in humid public halls.
Connections
| Connect | To |
|---|---|
| Amplifier output | Faston terminals |
| Further speakers | Additional outputs |
Setup
- Space the speakers evenly across the hall ceiling.
- Wire them to the amplifier outputs.
- Set a moderate background level.
- Walk the hall and adjust.
Tip: Even spacing gives a consistent level for visitors.
Workflow 6: Changing and shower rooms
Music and announcements in humid changing areas of sports centres.
Connections
| Connect | To |
|---|---|
| Zone amplifier | Faston terminals |
| Paging source | Amplifier input |
Setup
- Fit one speaker per room in the ceiling.
- Connect each to the zone amplifier.
- Fix the grille with the four screws.
- Test music and announcements.
Tip: Keep the cable entry dry and well sealed in the ceiling void.