ECLER eIC52MS product guide and data sheet cover
‹
ECLER eIC52MS product guide and data sheet coverECLER eIC52MS data sheet page 2: Overview, key features and designECLER eIC52MS data sheet page 3: Technical specifications and contact
›

Brand: ECLER

ECLER eIC52MS

MRP - Rs. 14,900

Category: Ceiling Loudspeakers | Series: eIC SERIES

ECLER eIC52MS two-way 5 inch marine / sauna in-ceiling loudspeaker, 20 W RMS, IP54, for high humidity. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.


Quantity:

−1+
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)

The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.


TECHNICAL SPECIFICATIONTech SpecsDESCRIPTIONDescriptionREAL-WORLD WORKFLOWSReal-World Workflows

System

Effective frequency range83 Hz - 20 kHz (-10 dB)
Coverage angle155° x 155° (H x V)
Power handling20 W RMS / 80 W peak
Sensitivity (1 W / 1 m)91 dB
Maximum SPL104 dB continuous / 110 dB peak
Recommended amplifier power40 W RMS

Transducers

Ways2
Low frequency driver5 inch woofer
High frequency driver1 inch tweeter
Nominal impedance8 Ω

Physical

ConnectionFaston male input terminals: 4.8 mm (+) and 2.8 mm (-)
InstallationIn‑ceiling, in‑wall
EnvironmentalIP54 rated
Grille fixing system4 x screw fixing system
External diameter165 mm
Internal diameter120 mm
Recommended cut‑out diameter125 mm
Required depth79 mm
Operating temperature-25 °C to 70 °C
Operating humidityBelow 90‑95 % RH
ColourWhite (RAL 9016)
Weight0.70 kg
Shipping dimensions (W x H x D)210 x 80 x 210 mm
Shipping weight1.2 kg
Pieces per box1

Product overview

The ECLER eIC52MS is a two-way marine / sauna in-ceiling loudspeaker for installations exposed to extreme humidity and/or temperature, with a 5 inch woofer, a 1 inch tweeter and 20 W RMS at 8 Ω.

IP54 rated and working from -25 °C to 70 °C with up to 90-95 % relative humidity, the eIC52MS brings music and announcements to saunas, spas, aquariums, ships and harbours. It connects with Faston male terminals (4.8 mm + and 2.8 mm -), fits a 125 mm cut-out with 79 mm of depth, and its white (RAL 9016) grille is held by four screws.

At 8 Ω, 80 W peak 20 W RMS
Humidity proof IP54
Sensitivity (1 W / 1 m) 91 dB
Coverage angle 155°

Key features

  • Two-way speaker: 5 inch woofer and 1 inch tweeter
  • 20 W RMS at 8 Ω, 80 W peak
  • Faston male input terminals: 4.8 mm (+) and 2.8 mm (-)
  • Suitable for extreme humidity and/or temperature: IP54, -25 °C to 70 °C
  • Four-screw grille fixing
  • In-ceiling or in-wall; acoustic simulation data files available

Built for wet and hot spaces

The IP54 rating and an operating range from -25 °C to 70 °C at up to 90-95 % relative humidity make the eIC52MS suitable for saunas, spas and marine use.

Clear two-way sound

A 5 inch woofer and a 1 inch tweeter cover 83 Hz to 20 kHz (-10 dB) with 91 dB sensitivity and 155° coverage, reaching 104 dB continuous and 110 dB peak.

Easy installation

The speaker needs a 125 mm cut-out and 79 mm of depth. Faston terminals take the cable and four screws fix the white RAL 9016 grille.

In the box

  • 1 x eIC52MS in-ceiling loudspeaker

ECLER eIC52MS: frequently asked questions

Can the eIC52MS be used in a sauna?

Yes. ECLER designed it for installations exposed to extreme humidity and/or temperature, including saunas and spas.

What amplifier does it need?

The eIC52MS is an 8 Ω loudspeaker; ECLER recommends an amplifier of 40 W RMS.

What cut-out does it need?

A 125 mm cut-out and 79 mm of installation depth; the external diameter is 165 mm.

How is it connected?

With Faston male input terminals: 4.8 mm for (+) and 2.8 mm for (-).

Where can I buy the ECLER eIC52MS in India?

The ECLER eIC52MS is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.

Workflow 1: Sauna

Music in a sauna cabin exposed to heat and humidity.

Connections

ConnectTo
8 Ω amplifier output (outside the cabin)Faston terminals
Speaker cable4.8 mm (+) / 2.8 mm (-)

Setup

  1. Cut a 125 mm hole in the ceiling; allow 79 mm of depth.
  2. Connect the cable to the Faston terminals, respecting polarity.
  3. Fit the speaker and fix the grille with its four screws.
  4. Set a comfortable level from the amplifier outside.

Tip: The speaker operates from -25 °C to 70 °C and up to 90-95 % relative humidity.

Workflow 2: Spa and wellness area

Relaxing background music in humid treatment rooms and pool areas.

Connections

ConnectTo
Low‑impedance amplifierSpeaker Faston terminals
Second speakerSeparate output or channel

Setup

  1. Plan one speaker per treatment room or zone.
  2. Install in the ceiling or wall with a 125 mm cut-out.
  3. Wire each speaker to the amplifier output.
  4. Balance the levels between rooms.

Tip: Allow about 40 W RMS of amplifier power per speaker, as ECLER recommends.

Workflow 3: Ships

Cabins and onboard spaces exposed to sea air and humidity.

Connections

ConnectTo
Amplifier outputFaston terminals
CableThrough the ceiling panel

Setup

  1. Choose the speaker positions in the cabin ceiling.
  2. Cut the 125 mm openings.
  3. Connect, fit and screw the grilles.
  4. Test each cabin.

Tip: The IP54 rating protects the speaker against dust and water splashes.

Workflow 4: Harbour buildings

Announcements and music in harbour offices and waiting areas.

Connections

ConnectTo
Amplifier outputSpeakers in each area
SourceAmplifier input

Setup

  1. Install the speakers in the ceiling of each area.
  2. Wire them to the amplifier outputs.
  3. Set the levels for clear announcements.
  4. Check coverage across the room.

Tip: 155° coverage spreads the sound widely below each speaker.

Workflow 5: Aquarium

Background sound in humid public halls.

Connections

ConnectTo
Amplifier outputFaston terminals
Further speakersAdditional outputs

Setup

  1. Space the speakers evenly across the hall ceiling.
  2. Wire them to the amplifier outputs.
  3. Set a moderate background level.
  4. Walk the hall and adjust.

Tip: Even spacing gives a consistent level for visitors.

Workflow 6: Changing and shower rooms

Music and announcements in humid changing areas of sports centres.

Connections

ConnectTo
Zone amplifierFaston terminals
Paging sourceAmplifier input

Setup

  1. Fit one speaker per room in the ceiling.
  2. Connect each to the zone amplifier.
  3. Fix the grille with the four screws.
  4. Test music and announcements.

Tip: Keep the cable entry dry and well sealed in the ceiling void.