The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Digital
| DSP | Floating point 32/64 bit |
| Sampling rate | 48 kHz |
| Resolution | 24 bit |
| Latency | Below 1.5 ms |
| Dynamic range | AD 111 dB, DA 115 dB |
Inputs
| Inputs 1, 2 (line) | RCA female with Euroblock stack, unbalanced; +5 / -15 dBV; above 13 kΩ |
| Inputs 3‑6 (MIC/LINE) | Euroblock, balanced; 0 / -50 dBV; above 24 kΩ |
| Pager inputs | Inputs 5 and 6, RJ‑45 |
| Phantom power | +48 V DC (rear panel switch) |
| Inputs 7‑14 (remote) | RJ‑45, balanced; 0 dBV; above 24 kΩ |
| Input headroom | 12 dBV |
| CMRR | Above 60 dB (20 Hz - 20 kHz) |
Outputs and performance
| Zone outputs | 8, line, Euroblock 3‑pin, balanced |
| Maximum output level | 12 dBV |
| Headphones | Output 1‑8 selectable, 3.5 mm mini‑jack, above 200 mW / 200 Ω |
| External mute | Normally open, assignable to any zone |
| Frequency response | Below 10 Hz to 20 kHz (+0 / -0.5 dB) |
| Output noise floor | Above 110 dB (20 Hz - 20 kHz) |
| THD+N | Below 0.005 % (1 kHz, 1 Vrms) |
| Crosstalk | Above 90 dB, 20 Hz - 20 kHz |
| Flatness | Better than ±0.1 dB |
Processing
| Input level (x14) | Off to 0 dB, mute, VU, polarity; stereo on inputs 3‑6 |
| Input high‑pass filter | 50 to 150 Hz (inputs 3‑6) |
| Frequency shifter | 5 Hz (inputs 3‑6) |
| Noise gate (x4) | Threshold -80 to +12 dBV, depth 0‑80 dB |
| Input / output tone | 3‑way, -10 to +10 dB; 200 Hz, 1 kHz, 6.3 kHz |
| Output graphic EQ (x8) | 8 bands, 63 Hz to 8 kHz, -10 to +10 dB |
| Output compressor (x8) | Threshold -36 to +12 dB, ratio 1 to 100 |
| Output delay (x8) | 0 to 300 ms |
| Output crossover (x8) | High or low pass, 20 Hz to 20 kHz |
| Ducker / pager | Four priority levels, priority volume -40 to +6 dB, chime melody 1 or 2 |
Control, electrical and physical
| Ethernet | 1 x RJ‑45, 10/100 Mb, CAT5 up to 100 m |
| Serial port | RS‑232, DB9 |
| Remote bus | RS485 |
| Aux. supply for remotes | +12 V DC, 0.6 A max, short‑circuit protected |
| Programming and control | HANGAR web application, ECLER pilot app, TP‑NET (UDP / RS‑232) |
| Mains | 100‑240 V AC, 50‑60 Hz, IEC C14 |
| Power consumption | 20 W |
| Operating temperature | -10 °C to 40 °C |
| Installation | 19 inch rack (2RU) |
| Dimensions (W x H x D) | 482.6 x 88 x 200 mm |
| Weight | 3.6 kg |
| Shipping dimensions (W x H x D) | 550 x 120 x 390 mm |
| Shipping weight | 5.6 kg |
Product overview
The ECLER HUB1408 is a plug and play digital zone manager with 14 inputs and 8 outputs, integrated DSP and the HANGAR web application embedded in the unit for configuration from any standard web browser.
Two stereo line inputs, four MIC/LINE inputs with phantom power and eight remote inputs on RJ-45 feed eight balanced zone outputs. End users control their zones from the front panel, up to 8 eMCONTROL1 wall panels, up to 2 eMPAGE paging stations or the ECLER pilot mobile app, while installers program everything from HANGAR with no software to install. Predefined setups get a professional installation running in minutes, and full DSP with four priority levels covers more demanding projects.
| Inputs and zone outputs | 14 x 8 |
| eMCONTROL1 wall panel ports | 8 |
| Priority levels, ducker / pager | 4 |
| 19 inch rack unit | 2RU |
Key features
- 14 inputs, 8 outputs digital zoner with integrated DSP
- HANGAR embedded web application: programming from a standard web browser
- 2 stereo line inputs (RCA and Euroblock), 4 MIC/LINE inputs with +48 V phantom, 8 remote inputs on RJ-45
- 8 balanced zone outputs, mono or stereo pairs
- Up to 8 eMCONTROL1 wall panels and 2 eMPAGE paging stations
- ECLER pilot app with custom graphic panels for end users
- Per zone: source selection, volume, MUTE, 3-band tone; general volume
- Four priority levels with ducker and pager functions and chimes
- DSP: frequency shifter, stereo link, delay, crossover, 8-band graphic EQ, compressor/limiter
- TP-NET over RS-232 (DB9) or Ethernet; MUTE port for an external dry contact
Plug and play
Four predefined setups cover the most common layouts: 8 mono zones with 2, 3 or 4 sources, and 4 stereo zones with 3 sources. Load one from HANGAR or from the pilot app, connect sources and amplifiers, and the system is ready; every parameter can then be refined.
Control for every user
The admin user decides what each user may change. End users select sources, adjust volume and tone and mute zones from eMCONTROL1 wall panels, the front panel, or graphic pilot panels on their phones and tablets, with optional minimum and maximum volume limits. Paging stations send announcements with zone selection and chimes.
Professional DSP
Inputs offer level, mute, polarity, 3-band tone, and on the MIC/LINE inputs a high-pass filter, noise gate and frequency shifter. Each zone output adds 3-band tone, an 8-band graphic EQ, compressor/limiter, delay up to 300 ms and crossover filters. Ducker and pager priorities use four levels with priority volume from -40 to +6 dB.
In the box
- 1 x HUB1408
- Mains power cord
- Warranty card
ECLER HUB1408: frequently asked questions
Do I need software to configure the HUB1408?
No. The HANGAR application is built into the unit and opens in a standard web browser.
How many wall panels and paging stations can I connect?
Up to 8 eMCONTROL1 wall panels on the REMOTE ports and up to 2 eMPAGE paging stations on PAGER A and B.
Can users control it from their phones?
Yes, with the ECLER pilot app, showing graphic panels set up by the admin user.
Can it integrate with control systems?
Yes, through the TP-NET protocol over Ethernet (UDP) or RS-232.
Where can I buy the ECLER HUB1408 in India?
The ECLER HUB1408 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Restaurant with 8 zones
Dining areas, bar and terrace with local control.
Connections
| Connect | To |
|---|---|
| TV and music player | IN1, IN2 |
| Zone amplifiers | OUTPUTS 1‑8 |
Setup
- Load the factory setup (8 zones mono, 2 sources).
- Connect the sources and amplifiers.
- Install eMCONTROL1 panels in each area.
- Give staff the pilot app for zone control.
Tip: Set minimum and maximum volume limits per zone in HANGAR.
Workflow 2: Retail store
Background music and announcements.
Connections
| Connect | To |
|---|---|
| eMPAGE paging station | PAGER A |
| Music player | IN1 |
Setup
- Load a predefined setup with the right number of sources.
- Set the paging station zones and chime.
- Set priority levels for announcements.
- Test every zone.
Tip: Up to 2 eMPAGE stations can be connected.
Workflow 3: Hotel common areas
Lobby, corridors, gym and spa.
Connections
| Connect | To |
|---|---|
| Local sources | IN1‑IN4 |
| Zone amplifiers | OUTPUTS 1‑8 |
Setup
- Configure zones and sources in HANGAR.
- Create pilot panels for reception staff.
- Set EQ and compressors per zone.
- Use the MUTE port with the alarm system.
Tip: The MUTE port mutes chosen zones from an external dry contact.
Workflow 4: School or university
Classrooms, corridors and playgrounds.
Connections
| Connect | To |
|---|---|
| Microphones | IN3‑IN4 (phantom on) |
| Building zones | OUTPUTS 1‑8 |
Setup
- Enable phantom power for condenser microphones.
- Set ducker priorities for announcements.
- Install wall panels in key rooms.
- Restrict front panel functions.
Tip: Set GAIN so peaks sit close to 0 dB on the VU meters.
Workflow 5: Stereo zones
Bars and showrooms that need stereo music.
Connections
| Connect | To |
|---|---|
| Stereo sources | IN1, IN2 |
| Stereo amplifiers | OUTPUTS 1‑2, 3‑4, 5‑6, 7‑8 |
Setup
- Load the 4 zones stereo, 3 sources setup.
- Link output pairs as stereo zones.
- Add delay and crossover as needed.
- Test source selection from the pilot app.
Tip: Stereo zones use natural pairs 1-2, 3-4 and so on.
Workflow 6: Control system integration
Venues with a central control processor.
Connections
| Connect | To |
|---|---|
| Control processor | RS‑232 (DB9) or ETHERNET |
| HUB1408 | TP‑NET commands |
Setup
- Connect the control processor.
- Map zone volume, source and mute commands.
- Read back status for feedback.
- Test every command.
Tip: Ethernet supports DHCP (factory) or a static IP.