ECLER HUB1616 product guide and data sheet cover
‹
ECLER HUB1616 product guide and data sheet coverECLER HUB1616 data sheet page 2: Overview and key featuresECLER HUB1616 data sheet page 3: Front panelECLER HUB1616 data sheet page 4: Rear panel and connectionsECLER HUB1616 data sheet page 5: Predefined setups and controlECLER HUB1616 data sheet page 6: Technical specificationsECLER HUB1616 data sheet page 7: Processing and contact
›

Brand: ECLER

ECLER HUB1616

MRP - Rs. 2,97,900

Category: Digital Audio Matrices & Processors | Series: HUB SERIES

ECLER HUB1616 plug and play 16x16 digital zoner with DSP, HANGAR web app, pilot app, wall panel and paging ports, 2RU. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.


Quantity:

−1+
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)

The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.


TECHNICAL SPECIFICATIONTech SpecsDESCRIPTIONDescriptionREAL-WORLD WORKFLOWSReal-World Workflows

Digital

DSPFloating point 32/64 bit
Sampling rate48 kHz
Resolution24 bit
LatencyBelow 1.5 ms
Dynamic rangeAD 111 dB, DA 115 dB

Inputs

Inputs 1‑4 (line)RCA female (inputs 1, 2 with Euroblock stack), unbalanced; +5 / -15 dBV; above 13 kΩ
Inputs 5‑8 (MIC/LINE)Euroblock, balanced; 0 / -50 dBV; above 24 kΩ
Pager inputsInputs 7 and 8, RJ‑45
Phantom power+48 V DC (rear panel switch)
Inputs 9‑16 (remote)RJ‑45, balanced; 0 dBV; above 24 kΩ
Input headroom12 dBV
CMRRAbove 60 dB (20 Hz - 20 kHz)

Outputs and performance

Zone outputs16, line, Euroblock 3‑pin, balanced
Maximum output level12 dBV
HeadphonesOutput 1‑16 selectable, 3.5 mm mini‑jack, above 200 mW / 200 Ω
External muteNormally open, assignable to any zone
Frequency responseBelow 10 Hz to 20 kHz (+0 / -0.5 dB)
Output noise floorAbove 110 dB (20 Hz - 20 kHz)
THD+NBelow 0.005 % (1 kHz, 1 Vrms)
CrosstalkAbove 90 dB, 20 Hz - 20 kHz
FlatnessBetter than ±0.1 dB

Processing

Input level (x16)Off to 0 dB, mute, VU, polarity; stereo on inputs 5‑8
Input high‑pass filter50 to 150 Hz (inputs 5‑8)
Frequency shifter5 Hz (inputs 5‑8)
Noise gate (x4)Threshold -80 to +12 dBV, depth 0‑80 dB
Input / output tone3‑way, -10 to +10 dB; 200 Hz, 1 kHz, 6.3 kHz
Output graphic EQ (x16)8 bands, 63 Hz to 8 kHz, -10 to +10 dB
Output compressor (x16)Threshold -36 to +12 dB, ratio 1 to 100
Output delayOutputs 1‑8, 0 to 300 ms
Output crossover (outputs 1‑8)High or low pass, 20 Hz to 20 kHz
Ducker / pagerFour priority levels, priority volume -40 to +6 dB, chime melody 1 or 2

Control, electrical and physical

Ethernet1 x RJ‑45, 10/100 Mb, CAT5 up to 100 m
Serial portRS‑232, DB9
Remote busRS485
Aux. supply for remotes+12 V DC, 0.6 A max, short‑circuit protected
Programming and controlHANGAR web application, ECLER pilot app, TP‑NET (UDP / RS‑232)
Mains100‑240 V AC, 50‑60 Hz, IEC C14
Power consumption20 W
Operating temperature-10 °C to 40 °C
Installation19 inch rack (2RU)
Dimensions (W x H x D)482.6 x 88 x 200 mm
Weight3.66 kg
Shipping dimensions (W x H x D)550 x 120 x 390 mm
Shipping weight5.66 kg

Product overview

The ECLER HUB1616 is a plug and play digital zone manager with 16 inputs and 16 outputs, integrated DSP and the HANGAR web application embedded in the unit for configuration from any standard web browser.

Four stereo line inputs, four MIC/LINE inputs with phantom power and eight remote inputs on RJ-45 feed sixteen balanced zone outputs. End users control their zones from the front panel, up to 8 eMCONTROL1 wall panels, up to 2 eMPAGE paging stations or the ECLER pilot mobile app, while installers program everything from HANGAR with no software to install. Predefined setups get a professional installation running in minutes, and full DSP with four priority levels covers more demanding projects.

Inputs and zone outputs 16 x 16
eMCONTROL1 wall panel ports 8
Priority levels, ducker / pager 4
19 inch rack unit 2RU

Key features

  • 16 inputs, 16 outputs digital zoner with integrated DSP
  • HANGAR embedded web application: programming from a standard web browser
  • 4 stereo line inputs (RCA; inputs 1-2 also Euroblock), 4 MIC/LINE inputs with +48 V phantom, 8 remote inputs on RJ-45
  • 16 balanced zone outputs, mono or stereo pairs
  • Up to 8 eMCONTROL1 wall panels and 2 eMPAGE paging stations
  • ECLER pilot app with custom graphic panels for end users
  • Per zone: source selection, volume, MUTE, 3-band tone; general volume
  • Four priority levels with ducker and pager functions and chimes
  • DSP: frequency shifter, stereo link, delay, crossover, 8-band graphic EQ, compressor/limiter
  • TP-NET over RS-232 (DB9) or Ethernet; MUTE port for an external dry contact

Plug and play

Four predefined setups cover the most common layouts: 16 mono zones with 2 or 4 sources, and 8 stereo zones with 4 or 6 sources. Load one from HANGAR or from the pilot app, connect sources and amplifiers, and the system is ready; every parameter can then be refined.

Control for every user

The admin user decides what each user may change. End users select sources, adjust volume and tone and mute zones from eMCONTROL1 wall panels, the front panel, or graphic pilot panels on their phones and tablets, with optional minimum and maximum volume limits. Paging stations send announcements with zone selection and chimes.

Professional DSP

Inputs offer level, mute, polarity, 3-band tone, and on the MIC/LINE inputs a high-pass filter, noise gate and frequency shifter. Each zone output adds 3-band tone, an 8-band graphic EQ, compressor/limiter; zone outputs 1 to 8 add delay up to 300 ms and crossover filters. Ducker and pager priorities use four levels with priority volume from -40 to +6 dB.

In the box

  • 1 x HUB1616
  • Mains power cord
  • Warranty card

ECLER HUB1616: frequently asked questions

Do I need software to configure the HUB1616?

No. The HANGAR application is built into the unit and opens in a standard web browser.

How many wall panels and paging stations can I connect?

Up to 8 eMCONTROL1 wall panels on the REMOTE ports and up to 2 eMPAGE paging stations on PAGER A and B.

Can users control it from their phones?

Yes, with the ECLER pilot app, showing graphic panels set up by the admin user.

Can it integrate with control systems?

Yes, through the TP-NET protocol over Ethernet (UDP) or RS-232.

Where can I buy the ECLER HUB1616 in India?

The ECLER HUB1616 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.

Workflow 1: Restaurant and bar with many zones

Dining areas, bar and terrace with local control.

Connections

ConnectTo
TV and music playerIN1, IN2
Zone amplifiersOUTPUTS 1‑16

Setup

  1. Load the factory setup (16 zones mono, 2 sources).
  2. Connect the sources and amplifiers.
  3. Install eMCONTROL1 panels in each area.
  4. Give staff the pilot app for zone control.

Tip: Set minimum and maximum volume limits per zone in HANGAR.

Workflow 2: Retail store

Background music and announcements.

Connections

ConnectTo
eMPAGE paging stationPAGER A
Music playerIN1

Setup

  1. Load a predefined setup with the right number of sources.
  2. Set the paging station zones and chime.
  3. Set priority levels for announcements.
  4. Test every zone.

Tip: Up to 2 eMPAGE stations can be connected.

Workflow 3: Hotel common areas

Lobby, corridors, gym and spa.

Connections

ConnectTo
Local sourcesIN1‑IN4
Zone amplifiersOUTPUTS 1‑16

Setup

  1. Configure zones and sources in HANGAR.
  2. Create pilot panels for reception staff.
  3. Set EQ and compressors per zone.
  4. Use the MUTE port with the alarm system.

Tip: The MUTE port mutes chosen zones from an external dry contact.

Workflow 4: School or university

Classrooms, corridors and playgrounds.

Connections

ConnectTo
MicrophonesIN5‑IN6 (phantom on)
Building zonesOUTPUTS 1‑16

Setup

  1. Enable phantom power for condenser microphones.
  2. Set ducker priorities for announcements.
  3. Install wall panels in key rooms.
  4. Restrict front panel functions.

Tip: Set GAIN so peaks sit close to 0 dB on the VU meters.

Workflow 5: Stereo zones

Bars and showrooms that need stereo music.

Connections

ConnectTo
Stereo sourcesIN1, IN2
Stereo amplifiersOUTPUTS 1‑2, 3‑4 ... 15‑16

Setup

  1. Load an 8 zones stereo setup (4 or 6 sources).
  2. Link output pairs as stereo zones.
  3. Add delay and crossover as needed.
  4. Test source selection from the pilot app.

Tip: Stereo zones use natural pairs 1-2, 3-4 and so on.

Workflow 6: Control system integration

Venues with a central control processor.

Connections

ConnectTo
Control processorRS‑232 (DB9) or ETHERNET
HUB1616TP‑NET commands

Setup

  1. Connect the control processor.
  2. Map zone volume, source and mute commands.
  3. Read back status for feedback.
  4. Test every command.

Tip: Ethernet supports DHCP (factory) or a static IP.