ECLER MIMO88
MRP - Rs. 5,01,900
ECLER MIMO88 8x8 digital audio matrix with DSP, EclerNet control, GPI/GPO, expandable to 16x16 with a second unit. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Digital engine and converters
| DSP | 2 x 32/64 bit |
| Sampling rate | 48 kHz |
| Resolution | 24 bit |
| Latency in to out | Below 2.9 ms (+1 ms for 16x16) |
| Dynamic range | AD 110 dB, DA 115 dB |
| Frequency response | 5 Hz to 24 kHz (-3 dB) |
| Flatness | Better than ±0.1 dB |
Analogue inputs and outputs
| Inputs | 8 (+8 in 16x16), MIC/LINE, terminal block, balanced |
| Input sensitivity | -50 dBV to +10 dBV in 0.5 dB steps |
| Input impedance | Balanced, above 4 kΩ |
| Maximum input level | +27 dBV = +30 dBu |
| Phantom power | +42 V DC, 5 mA max, software switched |
| Outputs | 8 (+8 in 16x16), LINE, terminal block, balanced |
| Maximum output level | +18 dBV = +21 dBu |
| Monitor outputs | 2, terminal block, balanced |
| Headphones | 1/4 inch jack, above 200 mW / 200 Ω |
| THD+N, 1 kHz | Below 0.004 % (line, 0 dBV); below 0.008 % (mic, -40 dBV) |
| Output noise floor | Better than 115 dB |
| Crosstalk | Better than 90 dB (100 dB typ.) |
| CMRR | 65 dB typ. |
Processing
| Input / output level | Off to 0 dB, mute, polarity, VU + clip metering |
| Delay | 0 to 1000 ms on inputs and outputs |
| Parametric EQ | 4 per input; 8 per output (8x8) or 4 (16x16); 20 Hz‑20 kHz, -60/+12 dB, Q 0.3‑200 |
| Crossover filters | Butterworth, Bessel, Linkwitz‑Riley, 6 to 24 dB/oct |
| Input noise gate | Threshold -80 to +18 dBV, depth 0‑80 dB |
| Input compressor | Threshold -36 to +18 dBV, ratio 1:1 to inf:1 |
| Output limiter | Threshold -36 to +18 dBV |
| Signal generator | Sine, polarity, white and pink noise |
| Mix matrix | 8x8 (one unit), 16x16 (two units) |
| Pager | 4 priorities, chime melody 1 or 2 |
Control and connectivity
| Ethernet | RJ‑45, 10/100 Mb, Auto X‑Over, CAT5 up to 100 m |
| Expansion LINK BUS | 16x16 ch., CAT5 crossover up to 100 m |
| Remote bus | 2, twisted pairs, up to 1 km |
| GPI | 8, 0 to 10 V DC or TTL level |
| GPO | 8, 3‑pole isolated relay, 1 A 48 V DC max |
| Serial port | RS‑232 |
| Programming and control | EclerNet Manager, TP‑NET (UDP), UCP control panels |
| Aux. supply for remotes and GPI | +12 V DC, 1.2 A max, short‑circuit protected |
| RTC | ±1 minute per year; retention about 1 month |
Electrical and physical
| Mains | 90‑264 V AC, 47‑63 Hz, IEC socket |
| Power consumption | 45 VA |
| Operating temperature | -10 °C to 40 °C |
| Operating humidity | Below 85 % |
| Installation | 19 inch rack (1RU) |
| Dimensions (W x H x D) | 482.6 x 44 x 266.5 mm |
| Weight | 3.5 kg |
| Shipping dimensions (W x H x D) | 590 x 70 x 380 mm |
| Shipping weight | 4.8 kg |
| Optional accessories | WPa series control panels, WPNETTOUCH, eMPAGE |
Product overview
The ECLER MIMO88 is an 8 in / 8 out digital audio matrix, fully programmable and linkable to a second unit to become a real 16x16 matrix, with routing from any input to any output.
Built for installed sound in a single rack unit, the MIMO88 combines 8 balanced MIC/LINE inputs with phantom power, 8 balanced line outputs, 2 monitor outputs and a headphone output with extensive DSP: parametric EQ, delays, gates, compressors, limiters, ducking, paging and an automatic mixer. It is programmed over Ethernet with EclerNet Manager and controlled from UCP user control panels, ECLER wall panels and paging consoles, GPI/GPO ports or third-party control systems through the TP-NET protocol.
| MIC/LINE in, LINE out | 8 x 8 |
| With a second linked MIMO88 | 16 x 16 |
| GPI and GPO ports | 8 + 8 |
| Sampling, latency below 2.9 ms | 48 kHz |
Key features
- Expandable to 16 x 16: link a second MIMO88 over the LINK BUS (CAT5 crossover, up to 100 m)
- 8 balanced MIC/LINE inputs with independent phantom power per input
- 8 balanced LINE outputs plus 2 MONITOR outputs usable as auxiliaries and a headphone jack
- Fully programmable and controllable via EclerNet software
- UCP user control panels on computers, tablets, smartphones and WPNETTOUCH
- TP-NET protocol over Ethernet or RS-232 for third-party control systems
- 8 GPI and 8 GPO ports; remote bus for digital wall panels and MPAGE16 paging consoles
- FREQUENCY SHIFTER on each input to help avoid acoustic feedback
- Presets and scheduled events based on calendar
- WPNET4KV and WPNET8K compatible control panels (retro-compatible firmware)
Extensive DSP
Every input and output has level, mute, polarity, VU metering, parametric EQ and up to 1000 ms of delay. Inputs add a noise gate, compressor/limiter and the frequency shifter; outputs add crossover filters and a limiter. The matrix sets independent crosspoint levels, links adjacent channels as stereo pairs and handles priority ducking, virtual and physical paging with chimes, an automatic mixer and a built-in signal generator.
Control your way
EclerNet Manager gives a real-time graphical view of all functions, presets, scheduled events, groups and firmware updates over Ethernet. End users get custom UCP control panels on their own devices, ECLER WPa wall panels connect to the GPI ports, and WPNETTOUCH panels and paging consoles connect to the two-wire remote bus up to 1 km away. Eight relay GPOs drive external equipment from presets or events.
Two units, one matrix
Set one MIMO88 to MASTER and the other to SLAVE, join them with a CAT5 crossover cable on the LINK BUS and the pair works as a real 16 inputs / 16 outputs matrix, with only 1 ms of extra latency.
In the box
- 1 x MIMO88 unit
- Warranty card
ECLER MIMO88: frequently asked questions
How do I program the MIMO88?
With the EclerNet Manager application over Ethernet, either through a network or point to point with a CAT5 cable.
Can it grow beyond 8 x 8?
Yes. Linking a second MIMO88 over the LINK BUS creates a real 16 x 16 matrix.
Can third-party control systems operate it?
Yes, through the TP-NET protocol over Ethernet (UDP) or RS-232.
Does it help against feedback?
Each input has a FREQUENCY SHIFTER function designed to help avoid acoustic feedback.
Where can I buy the ECLER MIMO88 in India?
The ECLER MIMO88 is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Conference and boardroom
Microphones, playback and room speakers with automatic mixing.
Connections
| Connect | To |
|---|---|
| Table microphones | IN 1‑6 (phantom on) |
| Room amplifier | OUT 1‑2 |
Setup
- Wire microphones and enable phantom power per input.
- Enable the automatic mixer on the microphone inputs.
- Set gates, EQ and the frequency shifter against feedback.
- Give the chairperson a UCP panel on a tablet.
Tip: The frequency shifter on each input helps avoid acoustic feedback.
Workflow 2: Restaurant and bar zones
Music sources sent to several zones with local control.
Connections
| Connect | To |
|---|---|
| Music players | IN 7‑8 |
| Zone amplifiers | OUT 1‑8 |
Setup
- Route the sources to each zone in the matrix.
- Connect WPa wall panels to the GPI ports for zone volume.
- Store day and night presets.
- Schedule preset changes with calendar events.
Tip: Mono or stereo processing is selectable per channel pair.
Workflow 3: Paging with priority
Announcements that duck the background music.
Connections
| Connect | To |
|---|---|
| Paging console | Remote bus |
| Zone amplifiers | OUT 1‑8 |
Setup
- Connect the MPAGE16 paging console to the remote bus.
- Set paging priorities and the chime.
- Define ducking depth on the music inputs.
- Test announcements in every zone.
Tip: The remote bus reaches up to 1 km over twisted pairs.
Workflow 4: 16 x 16 system
Projects that need more than 8 inputs and outputs.
Connections
| Connect | To |
|---|---|
| MIMO88 (MASTER) LINK BUS | MIMO88 (SLAVE) LINK BUS |
| Ethernet | MASTER unit |
Setup
- Set one unit to MASTER and the other to SLAVE.
- Link them with a CAT5 crossover cable up to 100 m.
- Check the LINK indicators.
- Program the pair as one 16x16 matrix in EclerNet Manager.
Tip: Linking adds only 1 ms of latency.
Workflow 5: Integration with room control
Systems run from a third-party touch panel.
Connections
| Connect | To |
|---|---|
| Control processor | Ethernet (UDP) or RS‑232 |
| Screen and lighting relays | GPO 1‑8 |
Setup
- Enable TP-NET control on Ethernet or RS-232.
- Map presets and levels to the control panel buttons.
- Link GPO relays to presets.
- Test the full sequence.
Tip: GPO relays switch up to 1 A at 48 V DC.
Workflow 6: Speaker processing
Matrix outputs feeding loudspeaker systems directly.
Connections
| Connect | To |
|---|---|
| OUT 1 | Full‑range amplifier |
| OUT 2 | Subwoofer amplifier |
Setup
- Set output crossover filters for each way.
- Add delay to time-align speakers.
- Set output EQ and limiters.
- Store the setup and protect it with a password.
Tip: Monitor outputs and the headphone jack let you listen to any point in the system.