ECLER WPaVOL-SR
PRICE ON ENQUIRY
ECLER WPaVOL-SR remote wall panel: volume and source selection, 0-10 V DC, RJ45. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
PRICE ON ENQUIRY. For the price, exclusive offers, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share a personalised quotation for Shivansh Electronics, Kolkata, West Bengal, India. All payments are processed securely through Razorpay, our trusted payment gateway partner.
Function
| Type | Remote wall panel control for one volume and source or preset selection |
| Format | Single‑gang EU format |
| Controls | LEVEL + SELECT (0, 1‑4) |
| Connector | RJ45 |
| Control | 0‑10 V DC REMOTE ports |
Connections
| RJ45 pin 2 | REMOTE VOL (10 V → 0 V = minimum → maximum) |
| RJ45 pin 6 | VCC +12 V / +10 V |
| RJ45 pins 1, 3, 7 | GND |
| RJ45 pins 4, 5 | Not connected |
| RJ45 pin 8 | REMOTE ZONE (0, 3, 5, 7, 10 V → OFF, Z1, Z2, Z3, Z4) |
Physical
| Finish | White (RAL 9016) |
| Enclosure material | ABS |
| Dimensions (W x H x D) | 86 x 86 x 38 mm (with surface‑mount box) |
| Weight | 0.14 kg |
| Operating temperature | -10 °C to 40 °C |
| Operating humidity | < 85 % RH |
| Storage temperature | -10 °C to 40 °C |
| Storage humidity | < 90 % RH |
| Shipping dimensions (W x H x D) | 120 x 210 x 80 mm |
| Shipping weight | 0.27 kg |
| Included accessories | Surface‑mount installation box |
| Reference | CWPAVOLSR2 |
Product overview
The ECLER WPaVOL-SR is a remote wall panel control for one volume management and source or preset selection. It works with every ECLER device that has a 0-10 V DC REMOTE control port, such as the NXA series, GPA series, MIMO88, MPA-R, ALMA and CA series, and connects over one RJ45 cable. The WPa series has a modern, elegant and discreet design, and a surface-mount installation box is included.
WPa is ECLER's series of remote control wall panels for systems and for interconnecting audio signals, with a modern, elegant and discreet design in white (RAL 9016). Every panel of the series comes with a surface-mount installation box, and a magnetic frame holds the front plate in place.
| Remote volume control | LEVEL |
| Source or preset, 0 + 4 positions | SELECT |
| Connection | RJ45 |
| Weight | 0.14 kg |
Key features
- LEVEL knob for remote volume control (0-10 V DC)
- SELECT knob for source or preset selection: 0 (off) and positions 1 to 4
- RJ45 connection for control voltage and power
- Internal jumpers: ALOG (analogue) / LIN (digital), +10 / +12 V
- Surface-mount installation box included
Works with ECLER REMOTE ports
The WPaVOL-SR sends a 0-10 V DC control voltage over a standard RJ45 cable: pin 2 carries the remote volume (10 V = minimum, 0 V = maximum) and pin 6 the +10 V / +12 V supply from the controlled device. It is compatible with ECLER devices that have a 0-10 V DC REMOTE port, such as the NXA series, GPA series, MIMO88, MPA-R, ALMA and CA series.
Source or preset selection
The SELECT knob has an off position (0) and positions 1 to 4. Pin 8 of the RJ45 sends 0, 3, 5, 7 or 10 V, which the ECLER device reads as OFF, Z1, Z2, Z3 or Z4 to change the source or recall a preset.
Analogue or digital control ports
Internal jumpers set the panel for analogue REMOTE ports (ALOG, +10 V: factory default) or for digital inputs such as MIMO88 GPI ports (LIN, +12 V).
In the box
- 1 x WPaVOL-SR wall panel
- 1 x surface-mount installation box
ECLER WPaVOL-SR: frequently asked questions
Which ECLER devices work with the WPaVOL-SR?
Any ECLER device with a 0-10 V DC REMOTE port, such as the NXA series, GPA series, MIMO88, MPA-R, ALMA and CA series.
What cable does it use?
A standard RJ45 network cable, wired as in the connection diagram (pins 2, 6 and a GND pin, plus pin 8 for selection).
How many sources or presets can be selected?
Four: SELECT positions 1 to 4, plus 0 for off.
What size is it?
86 x 86 x 38 mm (with surface-mount box), 0.14 kg.
Where can I buy the ECLER WPaVOL-SR in India?
The ECLER WPaVOL-SR is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Zone volume in a shop
Retail spaces that want staff to set the music level at the wall.
Connections
| Connect | To |
|---|---|
| WPaVOL‑SR RJ45 | 0‑10 V DC REMOTE port of the ECLER amplifier or matrix |
Setup
- Run a network cable from the panel to the REMOTE port.
- Wire pin 2 (remote volume), pin 6 (VCC) and a GND pin as in the connection diagram.
- Turn LEVEL and check the zone volume follows.
Tip: Turning LEVEL fully clockwise gives maximum volume (0 V on pin 2).
Workflow 2: Meeting room level control
Corporate rooms with their own speaker zone.
Connections
| Connect | To |
|---|---|
| WPaVOL‑SR | REMOTE input of the zone amplifier |
Setup
- Mount the panel by the door.
- Connect it to the REMOTE port of the zone.
- Set the maximum level on the amplifier, then hand control to the panel.
Tip: One panel controls one volume.
Workflow 3: Restaurant and bar music
Leisure venues where the level changes through the day.
Connections
| Connect | To |
|---|---|
| WPaVOL‑SR | ECLER amplifier REMOTE port |
Setup
- Install the panel where staff can reach it.
- Connect the RJ45 cable.
- Adjust LEVEL during service.
Tip: The discreet white panel suits most interiors.
Workflow 4: Digital (GPI) control ports
Systems controlled from MIMO88 GPI ports.
Connections
| Connect | To |
|---|---|
| WPaVOL‑SR RJ45 pin 6, 2, GND | GPI terminal (+, control, ground) |
Setup
- Open the panel and set the jumpers to LIN and +12 V.
- Wire RJ45 pin 6 to +, pin 2 to the control input and a GND pin to ground.
- Assign the GPI to the volume in the matrix set-up.
Tip: Factory default is ALOG and +10 V, for analogue REMOTE ports.
Workflow 5: Source or preset selection
Zones that choose between music sources or presets.
Connections
| Connect | To |
|---|---|
| WPaVOL‑SR RJ45 pin 8 | Second REMOTE / GPI input of the ECLER device |
Setup
- Wire pin 8 (REMOTE ZONE) and a GND pin to the selection input.
- Assign positions 1 to 4 to sources or presets in the device.
- Turn SELECT: 0 = off, 1 to 4 = the chosen source.
Tip: Pin 8 sends 0, 3, 5, 7 or 10 V for OFF and Z1 to Z4.
Workflow 6: Mounting the panel
Installers fitting the panel to a wall.
Connections
| Connect | To |
|---|---|
| Surface‑mount box | Wall |
Setup
- Fix the surface-mount box (or an in-wall box) where the panel is needed.
- Wire the cable to the screw terminals of module B; no soldering is needed.
- Screw module B into the box, then fit the magnetic frame C.
- Press the front plate A into place with care: the frame magnets exert considerable force.
Tip: The surface-mount box is included.