FONESTAR GAT-801-EN product guide and data sheet cover
‹
FONESTAR GAT-801-EN product guide and data sheet coverFONESTAR GAT-801-EN data sheet page 2: Overview and key featuresFONESTAR GAT-801-EN data sheet page 3: EN 54 design with fireproof enclosureFONESTAR GAT-801-EN data sheet page 4: 100 V line transformer and connectionsFONESTAR GAT-801-EN data sheet page 5: Installation and maintenanceFONESTAR GAT-801-EN data sheet page 6: Acoustic dataFONESTAR GAT-801-EN data sheet page 7: Technical specificationsFONESTAR GAT-801-EN data sheet page 8: GAT EN 54 range, downloads and contact
›

Brand: FONESTAR

FONESTAR GAT-801-EN

PRICE ON ENQUIRY

Category: PA Loudspeakers | Series: GAT SERIES

FONESTAR GAT-801-EN 8 inch EN 54-24 ceiling speaker, 100 V line, 10 W RMS, fireproof enclosure, steel grille. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.


VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)

PRICE ON ENQUIRY. For the price, exclusive offers, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share a personalised quotation for Shivansh Electronics, Kolkata, West Bengal, India. All payments are processed securely through Razorpay, our trusted payment gateway partner.


TECHNICAL SPECIFICATIONTech SpecsDESCRIPTIONDescriptionREAL-WORLD WORKFLOWSReal-World Workflows

Acoustic

StandardEN 54‑24 certified
Power20 W maximum, 10 W RMS
Speaker8 inch
Response310‑11,500 Hz
Sensitivity84 dB at 1 W / 4 m
Sound pressure93 dB at rated power / 4 m
Maximum sound pressure level93 dB (rated noise power / 4 m)

Impedance

10 W tap10 W RMS @ 100 V / 5 W RMS @ 70 V (1,000 Ω)
5 W tap5 W RMS @ 100 V / 2.5 W RMS @ 70 V (2,000 Ω)

Build

Dispersion180° @ 500 Hz; 165° @ 1 kHz; 95° @ 2 kHz; 65° @ 4 kHz
MaterialABS and steel grille
ConnectorsCeramic connector for cable with a cross‑section of 1.5‑4 mm²
Operating temperature-20 °C to +55 °C
ColourWhite (RAL 9016)
Dimensions226 mm Ø x 101 mm depth
Hole210 mm Ø
Weight1.1 kg
InstallationRapid installation system

Product overview

The FONESTAR GAT-801-EN is a 8 inch EN 54-24 certified ceiling loudspeaker with a 100 V line transformer, round steel grille and fireproof enclosure, for evacuation systems, speech and background music.

Thanks to its extensive experience in the installation of evacuation systems, FONESTAR has designed a series of EN 54 ceiling speakers in accordance with the European standard EN 54. The ABS body with a fireproof box and steel grille guarantees its integrity and operation in alarm and emergency situations. It delivers crisp, clean sound, and its wide coverage angle covers a larger surface depending on the ceiling height. For shopping centres, hospitals, business centres, sports facilities, industrial buildings and more.

Certified, type A EN 54‑24
20 W maximum 10 W RMS
Sensitivity (1 W / 4 m) 84 dB
Coverage at 1 kHz 165°

Key features

  • EN 54-24 certified ceiling loudspeaker, type A
  • 100 V line transformer, round steel grille and fireproof enclosure
  • 8 inch loudspeaker, 20 W maximum, 10 W RMS
  • Taps: 10 W RMS @ 100 V / 5 W RMS @ 70 V (1,000 Ω); 5 W RMS @ 100 V / 2.5 W RMS @ 70 V (2,000 Ω)
  • Response 310-11,500 Hz, sensitivity 84 dB at 1 W / 4 m, sound pressure 93 dB at rated power / 4 m
  • Wide coverage: 180° @ 500 Hz, 165° @ 1 kHz, 95° @ 2 kHz, 65° @ 4 kHz
  • Ceramic connector for cable with a cross-section of 1.5-4 mm²
  • Rapid installation system
  • Operating temperature -20 °C to +55 °C
  • White (RAL 9016)

Built for evacuation systems

The fireproof rear box and the steel grille keep the loudspeaker working in alarm and emergency situations, as EN 54-24 requires for voice alarm loudspeakers.

100 V line taps

Connect the black wire (COM) and the red wire for the higher tap or the white wire for the lower tap: 10 W RMS @ 100 V / 5 W RMS @ 70 V (1,000 Ω); 5 W RMS @ 100 V / 2.5 W RMS @ 70 V (2,000 Ω). Insulate the unused wire end.

Installation and maintenance

Qualified personnel must perform the installation. FONESTAR asks for regular visual checks of the ceiling mounting, housing and connection cable, and cleaning with a clean cloth without solvents.

In the box

  • GAT-801-EN EN 54 ceiling loudspeaker with rapid installation system

FONESTAR GAT-801-EN: frequently asked questions

Is the GAT-801-EN certified for voice alarm systems?

Yes. It is EN 54-24 certified (type A) for evacuation systems in accordance with the European standard EN 54.

Which taps are available?

10 W RMS @ 100 V / 5 W RMS @ 70 V (1,000 Ω); 5 W RMS @ 100 V / 2.5 W RMS @ 70 V (2,000 Ω).

What size hole does it need?

A 210 mm Ø cut-out. The loudspeaker measures 226 mm Ø x 101 mm depth and weighs 1.1 kg.

Where can I buy the FONESTAR GAT-801-EN in India?

The FONESTAR GAT-801-EN is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.

Workflow 1: Shopping centre voice alarm

Evacuation messages and background music in malls.

Connections

ConnectTo
Voice alarm amplifier, 100 V lineCOM and tap wires

Setup

  1. Cut the holes and run the fire-rated line cable.
  2. Connect COM (black) and the 10 W tap (red).
  3. Push the loudspeaker in until the clamps hold it.
  4. Test every zone from the voice alarm system.

Tip: Use the same tap across one zone for an even level.

Workflow 2: Hospital corridors

Clear announcements in health centres.

Connections

ConnectTo
PA / voice alarm amplifierCOM and tap wires

Setup

  1. Space the loudspeakers along the corridors.
  2. Use the 5 W tap in quiet areas.
  3. Insulate the unused wire.
  4. Check speech clarity in every corridor.

Tip: Regular visual checks keep the installation in order.

Workflow 3: School and university

Bells, announcements and evacuation messages.

Connections

ConnectTo
100 V line amplifierCOM and tap wires

Setup

  1. Install in classrooms, halls and corridors.
  2. Group the loudspeakers in zones.
  3. Keep the sum of the taps within the amplifier power.
  4. Run a test message.

Tip: The wide coverage angle reduces the number of loudspeakers per room.

Workflow 4: Hotel common areas

Lobbies, corridors and restaurants.

Connections

ConnectTo
100 V line amplifierCOM and tap wires

Setup

  1. Mount in the false ceiling.
  2. Select the tap for each area.
  3. Connect the line with the amplifier switched off.
  4. Set background music levels.

Tip: White (RAL 9016) grille blends into the ceiling.

Workflow 5: Office building

Paging and evacuation in business centres.

Connections

ConnectTo
Voice alarm system, 100 VCOM and tap wires

Setup

  1. Plan zones per floor.
  2. Install one loudspeaker per area as coverage allows.
  3. Wire COM and the chosen tap.
  4. Check every zone.

Tip: Qualified personnel must perform the installation.

Workflow 6: Sports facility

Announcements in halls and changing areas.

Connections

ConnectTo
100 V line amplifierCOM and tap wires

Setup

  1. Install in ceilings of halls and corridors.
  2. Use the 10 W tap for larger spaces.
  3. Insulate unused wire ends.
  4. Test levels at busy times.

Tip: Keep the loudspeakers away from heat sources and moisture.