GENELEC 4435A product guide and data sheet cover
‹
GENELEC 4435A product guide and data sheet coverGENELEC 4435A data sheet page 2: Overview and key featuresGENELEC 4435A data sheet page 3: Design, grilles and finishesGENELEC 4435A data sheet page 4: Connector panel and controlsGENELEC 4435A data sheet page 5: Installation in the ceilingGENELEC 4435A data sheet page 6: PoE+ power and system examplesGENELEC 4435A data sheet page 7: Network, inputs and Smart IP ManagerGENELEC 4435A data sheet page 8: Technical specificationsGENELEC 4435A data sheet page 9: Response, dimensions and packageGENELEC 4435A data sheet page 10: Downloads and contact
›

Brand: GENELEC

GENELEC 4435A

PRICE ON ENQUIRY

Category: Ceiling Loudspeakers | Series: SMART IP

GENELEC 4435A Smart IP in-ceiling speaker: PoE+ power, AES67 / Dante audio and control on one CAT cable, Euroblock input, round or square grille. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.


VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)

PRICE ON ENQUIRY. For the price, exclusive offers, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share a personalised quotation for Shivansh Electronics, Kolkata, West Bengal, India. All payments are processed securely through Razorpay, our trusted payment gateway partner.


TECHNICAL SPECIFICATIONTech SpecsDESCRIPTIONDescriptionREAL-WORLD WORKFLOWSReal-World Workflows

General

TypeTwo‑way active Smart IP in‑ceiling loudspeaker
MountingThree rotating latches; safety wire tab
GrillesMagnetically attached, round or square
Colour optionsBlack, Round Grille, White, Round Grille, Black, Square Grille, White, Square Grille

Acoustic performance

Lower cut‑off, -6 dB≤ 58 Hz
Upper cut‑off, -6 dB> 39 kHz
Frequency response70 Hz - 20 kHz (±2.5 dB)
Max short‑term SPL≥ 104 dB at 1 m (PoE+)
Max long‑term SPL≥ 96 dB at 1 m (PoE+)
Max peak SPL> 107 dB at 1 m (PoE+)
Self‑generated noise≤ 10 dB (A‑weighted) at 1 m
Harmonic distortionAt 85 dB SPL: 70‑200 Hz < 5 %, above 200 Hz < 0.5 %
Dispersion120° horizontal, 100° vertical

Drivers

Bass130 mm (5 in) cone
Treble19 mm (3/4 in) metal dome

Network, inputs and processing

Network connection100BASE‑TX, 1 x RJ45 (PoE power, audio‑over‑IP and management)
Streaming formatsAES67, Dante
Stream format32‑96 kHz, 16‑24 bit; one channel or the sum of two
Analogue input3‑pin Euroblock, balanced, 10 kOhm
Analogue level for 100 dB SPL at 1 m-6 dBu (maximum 24 dBu)
Crossover frequency2.9 kHz
0 dBFS at maximum sensitivity130 dB SPL nominal
User filters20: parametric notch, high and low frequency shelf, bass roll‑off, bass tilt, treble tilt
Notch filter rangesGain -20 to +2 dB, Q 0.1‑20, 10 Hz‑16 kHz
Sensitivity / delay-60 to 0 dB / 0‑98 ms
Minimum delay2.2 ms from the analogue input to the acoustic output

Amplifiers and power

Bass amplifier50 W short‑term, Class D
Treble amplifier50 W short‑term, Class D
PoE supply at switchPoE+ (IEEE 802.3at, Class 4) 30 W; PoE (IEEE 802.3af, Class 3) 15 W
CAT cableCAT 5, 5e or 6; maximum 100 m
Power consumptionIdle 5 W; ISS standby 4 W

Physical

Round grilleØ 288 x 165 mm
Square grille288 x 288 x 159 mm
Free depth needed162 mm
Weight3.5 kg (7.7 lb)
Operating conditionsIndoor, 15‑35 °C, non‑condensing humidity
Guarantee2 years

Product overview

The GENELEC 4435A brings Smart IP to the ceiling: an in-ceiling loudspeaker of the highest quality with the ease of installation, system scalability and simple operation of single-cable networked technology.

Designed for discreet installation, the durable two-way 4435A takes PoE+ power, AES67 / Dante audio and management on one CAT cable, stores power to deliver 104 dB of short-term SPL and also has a balanced analogue input. It fastens with a simple latch system and hides behind a low-profile magnetically attached grille: round or square, black or white. Designed and manufactured sustainably in Finland.

Max short‑term SPL at 1 m (PoE+) 104 dB
Frequency response (-6 dB) 58 Hz - 39 kHz
Class D amplifiers 50 W + 50 W
Weight 3.5 kg

Key features

  • Single CAT cable: PoE+ / PoE power, audio-over-IP and management
  • AES67 and Dante streams; one channel, the sum of two, or L / R / L+R
  • Balanced analogue input on a Euroblock connector
  • 130 mm (5 in) woofer and 19 mm (3/4 in) metal dome tweeter
  • 50 W + 50 W Class D amplifiers, active crossover at 2.9 kHz
  • 104 dB short-term, 96 dB long-term and over 107 dB peak SPL at 1 m
  • Simple latch mounting with safety wire tab and cut-out template
  • Magnetic grilles: round or square, black or white, paintable
  • 20 filters, delay and sensitivity in every loudspeaker
  • Smart IP Manager, public API and Smart IP Controller app
  • Made in Finland

Single-cable Smart IP connectivity

One standard CAT cable carries PoE+ power, uncompressed low-latency audio and management. Each 4435A can be used alone or freely networked with the other Smart IP models, synchronised to sub-microsecond level; stereo can be sent on the network and each loudspeaker set to L, R or L+R.

Easy, tidy installation

Trace the supplied cut-out template, connect the cables and lift the enclosure into the hole: three latches rotate outwards and clamp the ceiling board. The enclosure needs 162 mm of free depth and about 20 mm of smooth ceiling around the hole. A tab takes a secondary safety wire, and GENELEC offers pre-construction brackets (272-0039) for new buildings.

Grilles and finishes

The magnetically attached grille comes in the shape and colour ordered: round or square, black or white (4435AMR, 4435AWR, 4435AMS, 4435AWS). The metal mesh grille can be spray painted separately to match the interior.

Smart IP Manager, API and Controller app

Smart IP Manager gives installers device discovery, zones, profiles, delay, sensitivity and 20 filters per loudspeaker. A public API with ready-made drivers connects automation systems, and the free Smart IP Controller app gives end users volume, mute and power per zone.

In the box

  • 1 x GENELEC 4435A in-ceiling loudspeaker with latch system and safety wire attachment point
  • 1 x cut-out template
  • 1 x magnetically attached grille in the selected shape and colour
  • 1 x Euroblock connector for the analogue input
  • 1 x operating manual

GENELEC 4435A: frequently asked questions

How is the 4435A powered?

Over its CAT cable from an IP switch with PoE+ outputs (IEEE 802.3at), or from a PoE+ power injector with a standard switch. It also works with PoE (IEEE 802.3af); GENELEC recommends PoE+ for the full output.

How do I set up and control a 4435A system?

Installers use GENELEC's free Smart IP Manager software for device discovery, zones, levels, delay and room equalisation. Day-to-day control is through the public API from a house automation system, or the free Smart IP Controller app on a smartphone or tablet.

Which grille comes with the 4435A?

The grille ordered: round or square, in black or white. Grilles are also available separately and can be spray painted to match the ceiling.

Is a safety wire included?

No. The enclosure has a safety wire tab; GENELEC recommends using a secondary safety wire.

Where can I buy the GENELEC 4435A in India?

The GENELEC 4435A is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.

Workflow 1: Single-cable networked installation

Install 4435A units where only a CAT cable can be run.

Connections

ConnectTo
PoE+ IP switch portRJ45 Ethernet port of each 4435A (CAT 5 or better, up to 100 m)
Audio source on the networkAES67 or Dante stream
Installer computerSame network, running Smart IP Manager

Setup

  1. Connect each 4435A to its own PoE+ switch port (star topology, no daisy-chaining of network ports).
  2. Power up the loudspeaker; PoE+ power is negotiated automatically.
  3. Route the stream channels to the units in the network audio routing software.
  4. Discover the units in Smart IP Manager and assign them to zones.

Tip: Use gigabit managed switches with QoS, and budget 30 W per PoE+ port within the switch's total PoE capacity.

Workflow 2: Long cable runs and standard switches

Power loudspeakers through PoE+ injectors where the switch has no PoE.

Connections

ConnectTo
Standard IP switchData input of a PoE+ power injector
PoE+ power injector4435A Ethernet port

Setup

  1. Place one PoE+ injector per unit, close to the loudspeaker for long runs.
  2. Connect the switch to the injector and the injector to the unit.
  3. Check that each injector supplies full PoE+ power.
  4. Configure streams and zones as usual.

Tip: Cable loss is about 25 mW per metre; injectors near the loudspeakers keep more power available for audio peaks.

Workflow 3: Zones and profiles in Smart IP Manager

Organise many loudspeakers into zones that work as one system.

Connections

ConnectTo
Smart IP ManagerAll Smart IP units on the network

Setup

  1. Create zones and drag the units into them.
  2. Set mute and zone level with the - and + buttons.
  3. Store up to five profiles per zone with acoustic settings, input selection, level and delay.
  4. Recall a profile to change the whole zone at once.

Tip: Settings are stored inside each unit for instant recall, even after a power cut.

Workflow 4: Room equalisation and alignment

Compensate room acoustics and align loudspeakers.

Connections

ConnectTo
Smart IP Manager, Acoustics tabSelected unit or group
Measurement microphone and toolListening area

Setup

  1. Start from the factory setting (flat anechoic response).
  2. Set delay (0-98 ms) and sensitivity (-60 to 0 dB) to align the units.
  3. Use the 20 filters (notch, shelves, bass roll-off, bass tilt, treble tilt) against room colouration.
  4. Confirm by careful listening with known recordings.

Tip: Positive filter gain is possible: use it with care to keep headroom.

Workflow 5: Control by automation system or app

Give end users simple day-to-day control.

Connections

ConnectTo
House automation or control systemPublic Smart IP API over the network
Smartphone or tabletSmart IP Controller app over WiFi

Setup

  1. Integrate the units with the public API and GENELEC's ready-made drivers.
  2. Or install the free Smart IP Controller app for smaller installations.
  3. Give users volume, mute and power on/off per zone.
  4. Recall stored settings for different uses of the space.

Tip: ISS can power the units down when idle and wake them on an API command or an audio stream.

Workflow 6: Ceiling installation

Fit 4435A loudspeakers into an existing or new ceiling.

Connections

ConnectTo
Cut‑out templateCeiling board
CAT cable and analogue cableConnector panel with strain reliefs
Safety wireSafety wire tab

Setup

  1. Plan the cable route; in new buildings mark positions with 272-0039 pre-construction brackets.
  2. Trace the template and cut the hole (at least 162 mm free depth).
  3. Loosen the latch screws, connect the cables and safety wire, lift the unit in and tighten the latches.
  4. Fit the magnetic grille; set zones and levels in Smart IP Manager.

Tip: Leave about 20 mm of smooth ceiling around the hole for the flange.

Explore all the categories

Studio to stage, every category —

View all ›

Explore all the brands

Genuine gear from leading audio brands —

View all ›