RME OPTO-X
MRP - Rs. 46,232
RME OPTO-X optical extension board for the HDSPe MADI FX: optical MADI 3, word clock and the MIDI/AES port, for three optical MADI I/Os. Available in India from Shivansh Electronics, Kolkata, West Bengal, India.
VISUAL GUIDE — See Every Photo, Spec & Setup Step (PDF)
The price shown is the MAXIMUM RETAIL PRICE (MRP), inclusive of all taxes. For the best price, exclusive offers and discounted rates, delivery timelines, or any other information, please DM us or call +91 89818 07755 / +91 91477 00677. We will gladly share an exclusive coupon code that you can apply at checkout. All payments are processed securely through Razorpay, our trusted payment gateway partner.
OPTO-X
| Type | Extension board for the HDSPe MADI FX |
| MADI | 1 x optical I/O (MADI 3), FDDI duplex SC, up to 2000 m |
| Channels | 64 at 48 kHz, 32 at 96 kHz, 16 at 192 kHz |
| Word clock | BNC input and output |
| MIDI / AES | D‑sub for the MIDI and AES/EBU breakout cable |
| RME part number | OPTOX |
Product overview
The RME OPTO-X is an alternative extension board for the HDSPe MADI FX triple MADI card that replaces the standard coaxial MADI I/O with an optical MADI I/O, so the card has three optical MADI I/Os.
Like the standard BNC-X extension board it carries word clock input and output on BNC and the D-sub connector for the MIDI and AES/EBU breakout cable, with full functionality. Connections and functions are identical to the standard board; only MADI 3 changes from coaxial to optical (SC, up to 2,000 m of multi-mode fibre).
Compatible with
- RME HDSPe MADI FX (in place of the included BNC-X expansion board)
In the box
- RME OPTO-X extension board
RME OPTO-X: frequently asked questions
What changes compared with the standard expansion board?
Only MADI 3: it becomes an optical MADI I/O instead of coaxial BNC. Word clock, MIDI and AES/EBU stay the same.
How many optical MADI ports does the MADI FX then have?
Three optical MADI I/Os.
Where can I buy the RME OPTO-X in India?
The RME OPTO-X is available from Shivansh Electronics, Kolkata, West Bengal, India, with delivery across India.
Workflow 1: Three optical MADI ports
Connect three optical MADI devices to one HDSPe MADI FX.
Connections
| Connect | To |
|---|---|
| OPTO‑X | Expansion board connector of the HDSPe MADI FX |
| Third optical MADI device | OPTO‑X MADI 3 I/O |
Setup
- Switch the computer off and fit the OPTO-X instead of the BNC-X board.
- Connect it to the card with the ribbon cable.
- Connect the optical MADI cables.
- Route MADI 3 in TotalMix FX.
Workflow 2: Long fibre runs between stage and control room
Use optical MADI on all three ports for long distances.
Connections
| Connect | To |
|---|---|
| Stage MADI devices | MADI 1‑3 optical I/O |
| House word clock | OPTO‑X word clock IN |
Setup
- Run multi-mode fibre up to 2,000 m.
- Select the clock source in the Settings dialog.
- Use MIDI over MADI to control RME devices remotely.
- Enable redundancy mode if needed.